AXL F CNT2 INC2 1F 2688093 PHOENIX CONTACT Axioline F special function module, 2 counter inputs, 2 increment.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AXL F CNT2 INC2 1F 2688093 PHOENIX CONTACT Axioline F special function module, 2 counter inputs, 2 increment..

AXL F CNT2 INC2 1F

2688093

PHOENIX_CONTACT

Available

Ship on today

Axioline F special function module, 2 counter inputs, 2 incremental encoder inputs (including bus base module and connectors)

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The module is designed for use within an Axioline˽F station.

On the one hand, it is used to acquire fast pulse sequences from sensors, and on the other hand to detect positions using incremental encoders.

The module combines two counter inputs for the evaluation of fast counter pulses and two incremental encoder inputs for position detection.

Dimensions

Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Net weight233.9 g
Note on weight specificationswith connectors and bus base module
Mounting typeDIN rail
Diagnostics messagesShort-circuit / overload of the digital outputs Yes
Error at the symmetrical incremental encoder Yes

Interfaces

DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s

Axioline potentials

Communications power UBus5 V DC (via bus base module)
Current consumption from UBustyp. 100 mA
max. 120 mA
Supply of digital input modules UI24 V DC
Current consumption from UItyp. 50.5 mA (Own current consumption; without wiring of the terminal points)
max. 2.5 A (dependent on the encoder or sensor type used and the load on the digital output.)

Counter inputs

Input nameCounter input for 24 V signals
Number of inputs2 (S1, S2)
Description of the inputEN 61131-2, type 3
Connection methodPush-in connection
Input voltage24 V DC
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Input frequencymax. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware)
Input current2.5 mA (per channel)
Resolution32
Permissible cable length to the sensor30 m

Encoder inputs

Input nameIncremental encoder inputs
Number of inputs2 (A1, /A1, B1, /B1, Z1, /Z1; A2, /A2, B2, /B2, Z2, /Z2)
Connection methodPush-in connection
Encoder signalsSymmetrical and asymmetrical encoders
Cable length30 m

Encoder data

Number of 5 V encoder supplies2 (UE1, UE2)
Nominal output voltage5 V DC
Voltage range5 V DC ... 5.5 V DC
Current carrying capacitymax. 250 mA
Type of protectionShort-circuit protection
Protective circuit/componentElectronic
Number of 24 V encoder supplies2 (US1, US2)
Nominal output voltage24 V DC
Voltage range19.2 V DC ... 30 V DC
Current carrying capacitytyp. 500 mA
Type of protectionShort-circuit protection
Protective circuit/componentElectronic
DesignationSymmetrical incremental encoders
Encoder types that can be connectedmax. 2 (A, /A, B, /B, (Z, /Z))
Type of connection of signalsPush-in connection
Encoder supply voltage5 V DC
24 V DC
Signal voltage levelDifferential signal (signal – inverted signal) ±0.5 V, minimum; ±6 V, maximum
Common mode voltage range signal - ground-10 V ... 13.2 V
Input frequencymax. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware)
DesignationAsymmetrical incremental encoders
Encoder types that can be connectedmax. 2 (A, B, (Z))
Type of connection of signalsPush-in connection
Signal voltage levelLow ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
Input frequencymax. 300 kHz (1 channel wired)
max. 100 kHz (More than one channel wired or Z signal monitoring via the firmware)

Digital inputs

Input nameDigital inputs
Description of the inputEN 61131-2, type 3
Connection methodPush-in connection
1-wire (optionally 2, 3-wire)
Number of inputs8 (CNT: G1, G2, Dir1, Dir2; INC: Ref1, Ref2, L1, L2)
Input voltage range "0" signal-3 V DC ... 5 V DC
Input voltage range "1" signal11 V DC ... 30 V DC
Nominal input current at UIN2.5 mA (per channel)

Digital outputs

Output nameDigital outputs
Connection methodPush-in connection
1-wire
Number of outputs2 (Out1, Out2)
Protective circuitShort-circuit protection, overload protection of the outputs
Output voltage24 V DC
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Nominal load, inductivemax. 12 VA (1.2 H; 48 Ω; with nominal voltage)
Nominal load, lampmax. 12 W (at nominal voltage)
Nominal load, ohmicmax. 12 W (48 Ω; with nominal voltage)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2688093-AXL F CNT2 INC2 1FEnglish186 KbytesPHOENIX CONTACT-2688093-AXL F CNT2 INC2 1F

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or