Socket attachment plug with surge protection for the power supply and signal connection of a termination device with analog or digital telecommunications interface (VDSL up to 46 Mbps). Cable is included.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for transceiver systems - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$48.14
5+$44.59
10+$43.52
14+$43.07
19+$42.76
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height103 mm
Width63 mm
Depth78 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 75 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C

General

Housing materialPA 6
Flammability rating according to UL 94V-0
Standards for cearances and creepage distancesVDE 0110-1
IEC 60664-1
IEC 61643-1
EN 61643-11
Total surge current (8/20) µs10 kA
Colorjet black RAL 9005
For country-specific use inB, F, CZ, SVK, PL
Mounting typePlugging into the mains socket
TypeAttachment plug
Direction of actionL/N-PE & Signal Line-Earth Ground

Protective circuit, power supply

IEC test classificationIII
T3
EN typeT3
Nominal voltage UN230 V AC
Arrester rated voltage UC (L-N)275 V AC
Arrester rated voltage UC (L-PE)360 V AC
Arrester rated voltage UC (N-PE)360 V AC
Nominal frequency fN50 Hz (60 Hz)
Standby power consumption PC≤ 1 VA
Residual current IPE≤ 5 µA
Nominal discharge current In (8/20) µs3 kA (> 5x)
Combination wave UOC4 kV
Energy absorption symmetrical140 J (L-N)
Enery absorption, asymmetrical220 J (L(N)-PE)
Voltage protection level Up (L-N)≤ 1.2 kV
Voltage protection level Up (L-PE)≤ 1.5 kV
Voltage protection level Up (N-PE)≤ 1.5 kV
Total surge current (8/20) µs10 kA
Response time (L-N)≤ 25 ns
Response time (L-PE)≤ 100 ns
Response time (N-PE)≤ 100 ns
Surge protection fault messageoptical
Max. required back-up fuse16 A AC (gG / B / C)

Connection (protective circuit, power supply)

Connection methodGrounding plug/socket
Connection type INProtective contact plug CEE7
Connection type OUTProtective contact socket CEE7

Protective circuit, information technology

Arrester rated voltage UC (Core-Core)200 V DC
Arrester rated voltage UC (Core-Earth)380 V DC
Nominal current IN1.5 A (25 °C)
Operating effective current IC at UC≤ 150 µA
Residual current IPE≤ 2 µA
Insulation resistance Riso≥ 1 MΩ
≥ 1 GΩ
Nominal discharge current In (8/20) µs (Core-Core)1 kA
Nominal discharge current In (8/20) µs (Core-Earth)2.5 kA
Max. discharge current Imax (8/20) µs2.5 kA
Voltage protection level Up (core-core)≤ 460 V (C2 - 1 kA)
≤ 350 V (C3 - 25 A)
Voltage protection level Up (core-ground)≤ 900 V (C2 - 2 kA)
≤ 900 V (C3 - 100 A)
Response time tA (Core-Core)≤ 25 ns
Response time tA (Core-Earth)≤ 100 ns
Cut-off frequency fg (3 dB), sym. in 100 Ohm systemtyp. 4 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ohm systemtyp. 3 MHz
Cut-off frequency fg (3 dB), sym. in 600 Ohm systemtyp. 700 kHz
Capacity (Core-Core)typ. 1 nF
Capacity (Core-Earth)typ. 5 pF
Output voltage limitation at 1 kV/µs (wire-wire)≤ 360 V
Residual voltage at In (conductor-conductor)≤ 500 V
Residual voltage at In (conductor-ground)≤ 30 V
Residual voltage with Ian (10/1000)µs (conductor-conductor)≤ 35 V
Residual voltage with Ian (10/1000)µs (conductor-ground)≤ 35 V
Impulse durability (conductor-conductor)C2 - 2 kV / 1 kA
C3 - 25 A
Impulse durability (conductor-ground)C2 - 4 kV/2 kA
C3 - 100 A
D1 - 500 A
Alternating current carrying capacity (conductor-conductor)250 mA - 1 s
Alternating current carrying capacity (conductor-ground)10 A - 1 s
Pulse reset time (conductor-conductor)≤ 10 ms

Power supply, general

Connection methodRJ12
Connection type INRJ12 female connector
Connection type OUTRJ12 female connector

Connection, equipotential bonding, information technology

Connection methodVia protective contact plug

Standards (protective circuit, information technology)

IEC test classificationC1
C2
C3
D1

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2882404-MNT-TEL B/FEnglish118 KbytesPHOENIX CONTACT-2882404-MNT-TEL B/F

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or