Product successfully added to your shopping cart
PSR-SPP- 24UC/URM4/5X1/2X2/B
2981046
PHOENIX_CONTACT
1
Extension module
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2981046 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 263 (C-6-2017) |
GTIN | 4017918915520 |
Weight per Piece (excluding packing) | 20.400 g |
Custom tariff number | 85371098 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -20 °C ... 55 °C (observe derating) |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 70 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | max. 2000 m (Above sea level) |
Rated control circuit supply voltage US | 24 V AC/DC -15 % / +10 % |
---|---|
Rated control supply current IS | typ. 81 mA AC |
typ. 71 mA DC | |
Power consumption at US | typ. 1.94 W (AC) |
typ. 1.7 W (DC) | |
Inrush current | 175 mA (Δt = 5 ms at Us) |
Typ. starting time with Us | < 20 ms (when controlled via A1) |
Typical release time | < 20 ms (when controlled via A1) |
Recovery time | < 1 s |
Operating voltage display | 1 x green LED |
Protective circuit | Surge protection Varistor |
Maximum switching frequency | 1 Hz |
Filter time | 2 ms (at A1 in the event of voltage dips at Us) |
Contact type | 5 enabling current paths |
---|---|
1 confirmation current path | |
1 signaling current path | |
Contact material | AgSnO2 |
Maximum switching voltage | 250 V AC/DC (Observe the load curve) |
Minimum switching voltage | 5 V AC/DC |
Limiting continuous current | 6 A (N/O contact, pay attention to the derating) |
6 A (N/C contact) | |
Maximum inrush current | 20 A (Δt 100 ms) |
Inrush current, minimum | 10 mA |
Sq. Total current | 72 A2(observe derating) |
Interrupting rating (ohmic load) max. | 144 W (24 V DC, τ = 0 ms) |
288 W (48 V DC, τ = 0 ms) | |
110 W (110 V DC, τ = 0 ms) | |
88 W (220 V DC, τ = 0 ms) | |
1500 VA (250 V AC, τ = 0 ms) | |
Maximum interrupting rating (inductive load) | 42 W (24 V DC, τ = 40 ms) |
42 W (48 V DC, τ = 40 ms) | |
42 W (110 V DC, τ = 40 ms) | |
42 W (220 V DC, τ = 40 ms) | |
Switching capacity min. | 50 mW |
Mechanical service life | 10x 106cycles |
Switching capacity (360/h cycles) | 4 A (24 V DC) |
4 A (230 V AC) | |
Output fuse | 10 A gL/gG (N/O contact) |
6 A gL/gG (N/C contact) |
Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
---|---|
Nominal operating mode | 100% operating factor |
Net weight | 20.4 g |
Mounting position | vertical or horizontal |
Mounting type | DIN rail mounting |
Assembly instructions | See derating curve |
Degree of protection | IP20 |
IP54 | |
Min. degree of protection of inst. location | IP54 |
Housing material | PBT |
Housing color | yellow |
Connection method | Spring-cage connection |
---|---|
pluggable | Yes |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Stop category | 0 |
---|---|
Designation | IEC 61508 - High demand |
Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
Designation | IEC 61508 - Low demand |
Safety Integrity Level (SIL) | 3 (In conjunction with suitable evaluating device) |
Designation | EN ISO 13849 |
Performance level (PL) | e (In conjunction with suitable evaluating device) |
Category | 4 (In conjunction with suitable evaluating device) |
Designation | EN 62061 |
Safety Integrity Level Claim Limit (SIL CL) | 3 (In conjunction with suitable evaluating device) |
Designation | Air clearances and creepage distances between the power circuits |
---|---|
Standards/regulations | DIN EN 50178/VDE 0160 |
Rated insulation voltage | 250 V AC |
Rated surge voltage/insulation | Basic insulation 4 kV: between all current paths and housing Safe isolation, reinforced insulation 6 kV: between A1/A2, 11/12, 23/24, 71/72 and 33/34, 43/44, 53/54, 63/64 |
Degree of pollution | 2 |
Overvoltage category | III |
Shock | 15g |
Vibration (operation) | 10 Hz ... 150 Hz, 2g |
Conformance | CE-compliant |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2981046-PSR-SPP- 24UC/URM4/5X1/2X2/B | 122 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.