PACT RCP-4000A-1A-D190 2904923 PHOENIX CONTACT Current transformer View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PACT RCP-4000A-1A-D190 2904923 PHOENIX CONTACT Current transformer

PACT RCP-4000A-1A-D190

2904923

PHOENIX_CONTACT

Current transformer

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $356.22
Unit price: $356.22

Quantity Price
1+$356.22
2+$355.67
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Viewed products


Often bought together

More info



Key Commercial Data

Orderkey2904923
Packing unit1 pc
Catalog pagePage 236 (C-5-2017)
GTIN4046356900935
Weight per Piece (excluding packing)455.400 g
Custom tariff number85437090
Country of originDE (Germany)

Measuring transducer supply

Nominal supply voltage24 V DC -20 % ... +25 %
Nominal supply voltage range19.2 V DC ... 30 V DC
Max. current consumption190 mA
Power consumption4 W

Measuring coil input data

Frequency measuring range40 Hz ... 20000 Hz
Position error< 1 %
Linearity error0.1 %

Measuring transducer input data

Measuring ranges (current)100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
Configurable/programmableVia DIP switches
Phase angle< 1 °
Rated power1.5 VA
Max. distances for copper cables at PN max32 m (0.75 mm² (AWG 20))
64 m (1.5 mm² (AWG 16))
107 m (2.5 mm² (AWG 14))

Measuring transducer signal input

Input signal (at 50 Hz)100 mV (1000 A)
Input impedance27 kΩ (smallest measuring range)

Measuring coil signal output

Output signal (at 50 Hz)100 mV (no load, at 1,000 A)
Output voltage (in no-load operation)VOUT= M * dI/dt
Output voltage (sinusoidal, in no-load operation)100 mV (VOUT= 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))

Measuring transducer signal output

Current output signal0 A AC ... 1 A
Load0 Ω ... 1.5 Ω

General data, measuring coil

Length of measuring coil600 mm
Diameter of measuring coil8.3 mm ±0.2 mm
Length of signal cable3000 mm
Conductor structure signal line2x 0.22 mm (Signal (tinned))
1x 0.22 mm (Shielding (tinned))
Coil materialElastollan
Housing materialPC
Insulationdouble insulation
Rated insulation voltage1000 V AC (rms CAT III)
600 V AC (rms CAT IV)
Test voltage10.45 kV (DC / 1 min.)
Basic accuracy
UL, USA/CanadaUL 61010 Recognized

General data for measuring transducer

Linearity error< 0.5 % (From the range end value)
Maximum transmission error≤ 0.5 % (From the range end value)
Frequency range45 Hz ... 65 Hz
Max. detectable harmonics< 2 kHz
Current consumption< 190 mA (at 19.2 V)
Housing materialPolyamide
Test voltage1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
Operating voltage displayGreen LED
UL, USA/CanadaUL 508 Listed

General data

Standards/regulationsIEC 61010-1
IEC 61010-2-032
Insulationdouble insulation
Degree of pollution2
Overvoltage categoryIII (1,000 V, to neutral conductor)
IV (600 V, to neutral conductor)
Temperature coefficients0.005 %/K (+10°C ... +70°C; both components have the same ambient temperature)
0.07 %/K (-20°C ... +10°C; both components have the same ambient temperature)
Typical measuring error< 1 %

Connection data

Connection nameMeasuring transducer side
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Screw threadM3
Connection methodScrew connection
Stripping length7 mm
Torque0.5 Nm ... 0.6 Nm

Dimensions

Width22.50 mm
Height85.00 mm
Depth70.40 mm

Ambient conditions

Ambient temperature (operation)-30 °C ... 80 °C (Measuring coil)
-20 °C ... 70 °C (Measuring transducer)
Ambient temperature (storage/transport)-40 °C ... 80 °C (Measuring coil)
-25 °C ... 85 °C (Measuring transducer)
Maximum altitude< 2000 m
Measuring coil degree of protectionIP67 (not assessed by UL)
Measuring transducer degree of protectionIP20

Standards and Regulations

Standards/regulationsIEC 61010-1
IEC 61010-2-032
Insulationdouble insulation
Degree of pollution2
Overvoltage categoryIII (1,000 V, to neutral conductor)
IV (600 V, to neutral conductor)

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (1)

  • N Jim
    Customer rating:
  • Page:1
    Add Review
    hide form
    Rating:
    Name:
    Email:
    Subject:
    Text:
      Captcha
      Add review

    All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.