PACT RCP-4000A-1A-D140 2904922 PHOENIX CONTACT Set consisting of 2 components: 1 A measuring transducer and .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PACT RCP-4000A-1A-D140 2904922 PHOENIX CONTACT Set consisting of 2 components: 1 A measuring transducer and ..

PACT RCP-4000A-1A-D140

2904922

PHOENIX_CONTACT

Available

Ship on today

Set consisting of 2 components: 1 A measuring transducer and a Rogowski coil, length 450 mm. The measuring coil diameter when installed is 140 mm. The Rogowski coil is used for AC current measurement for busbars and power lines.

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$281.04
2+$274.67
3+$271.86
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Measuring transducer supply

Nominal supply voltage24 V DC -20 % ... +25 %
Nominal supply voltage range19.2 V DC ... 30 V DC
Max. current consumption190 mA
Power consumption4 W

Measuring coil input data

Frequency measuring range40 Hz ... 20000 Hz
Position error< 1 %
Linearity error0.1 %

Measuring transducer input data

Measuring ranges (current)100 A 250 A 400 A 630 A 1000 A 1500 A 2000 A 4000 A
Configurable/programmableVia DIP switches
Phase angle< 1 °
Rated power1.5 VA

Measuring transducer signal input

Input signal (at 50 Hz)100 mV (1000 A)
Input impedance27 kΩ (smallest measuring range)

Measuring coil signal output

Output signal (at 50 Hz)100 mV (no load, at 1,000 A)
Output voltage (in no-load operation)VOUT = M * dI/dt
Output voltage (sinusoidal, in no-load operation)100 mV (VOUT = 2 * π * M * f * I (M = 0.318 μH; example: At 50 Hz; I = 1,000 A))

Measuring transducer signal output

Current output signal0 A AC ... 1 A AC
Load0 Ω ... 1.5 Ω
Operating voltage displayGreen LED

General data, measuring coil

Length of measuring coil450 mm
Diameter of measuring coil8.3 mm ±0.2 mm
Length of signal cable3000 mm
Conductor structure signal line2x 0.22 mm (Signal (tinned))
1x 0.22 mm (Shielding (tinned))
Coil materialElastollan
Housing materialPC
Insulationdouble insulation
Rated insulation voltage1000 V AC (rms CAT III)
600 V AC (rms CAT IV)
Test voltage10.45 kV (DC / 1 min.)
Basic accuracy<± 0.21 %
UL, USA / CanadaUL 61010 Recognized

General data for measuring transducer

Linearity error< 0.5 % (From the range end value)
Maximum transmission error≤ 0.5 % (From the range end value)
Frequency range45 Hz ... 65 Hz
Current consumption< 190 mA (at 19.2 V)
Housing materialPolyamide
Degree of protectionIP20
Test voltage1.5 kV AC (Supply/input and output: 50 Hz, 1 min)
UL, USA / CanadaUL 508 Listed

General data

Standards/regulationsIEC 61010-1
IEC 61010-2-032
Insulationdouble insulation
Pollution degree2
Overvoltage categoryIII (1,000 V, to neutral conductor)
IV (600 V, to neutral conductor)
Temperature coefficients0.005 %/K (+10°C ... +70°C; both components have the same ambient temperature)
0.07 %/K (-20°C ... +10°C; both components have the same ambient temperature)
Typical measuring error< 1 %

Connection data

Connection nameMeasuring transducer side
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Screw threadM3
Connection methodScrew connection
Stripping length7 mm
Torque0.5 Nm ... 0.6 Nm

Dimensions

Width22.50 mm
Height70.40 mm
Depth85.00 mm

Ambient conditions

Ambient temperature (operation)-30 °C ... 80 °C (Measuring coil)
-20 °C ... 70 °C (Measuring transducer)
Ambient temperature (storage/transport)-40 °C ... 80 °C (Measuring coil)
-25 °C ... 85 °C (Measuring transducer)
Maximum altitude< 2000 m
Measuring coil degree of protectionIP67 (not assessed by UL)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2904922-PACT RCP-4000A-1A-D140English100 KbytesPHOENIX CONTACT-2904922-PACT RCP-4000A-1A-D140

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or