Product successfully added to your shopping cart
PSR-SPP- 24UC/URM/5X1/2X2
2963970
PHOENIX_CONTACT
1
Coupling relay
Safety
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2963970 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 277 (C-6-2017) |
GTIN | 4017918904791 |
Weight per Piece (excluding packing) | 137.480 g |
Custom tariff number | 85364900 |
Country of origin | DE (Germany) |
Ambient temperature (operation) | -20 °C ... 55 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | 75 % (on average, 85% infrequently, non-condensing) |
Max. permissible humidity (storage/transport) | 75 % (on average, 85% infrequently, non-condensing) |
Maximum altitude | max. 2000 m (Above sea level) |
Rated control circuit supply voltage US | 24 V AC/DC -15 % / +10 % |
---|---|
Rated control supply current IS | typ. 47 mA |
Power consumption at US | typ. 1.2 W |
Inrush current | typ. 350 mA DC (Δt s) |
typ. 350 mA AC (Δt = 2 ms at Us) | |
Typ. starting time with Us | typ. 20 ms (when controlled via A1) |
Typical release time | typ. 20 ms (when controlled via A1) |
Recovery time | < 500 ms |
Operating voltage display | 1 x green LED |
Protective circuit | Surge protection Varistor |
Maximum switching frequency | 0.5 Hz |
Contact type | 5 enabling current paths |
---|---|
2 confirmation current paths | |
Contact material | AgSnO2 |
Maximum switching voltage | 230 V AC/DC (Observe the load curve) |
Minimum switching voltage | 5 V AC/DC |
Limiting continuous current | 6 A (N/O contact) |
3 A (N/C contact) | |
Maximum inrush current | 6 A |
Inrush current, minimum | 10 mA |
Sq. Total current | 72 A2 |
Interrupting rating (ohmic load) max. | 144 W (N/O contact, 24 V DC, τ = 0 ms) |
288 W (N/O contact, 48 V DC, τ = 0 ms) | |
240 W (N/O contact, 60 V DC, τ = 0 ms) | |
110 W (N/O contact, 110 V DC, τ = 0 ms) | |
88 W (N/O contact, 220 V DC, τ = 0 ms) | |
1380 VA (N/O contact, 230 V AC, τ = 0 ms) | |
Maximum interrupting rating (inductive load) | 42 W (N/O contact, 24 V DC, τ = 40 ms) |
42 W (N/O contact, 48 V DC, τ = 40 ms) | |
42 W (N/O contact, 60 V DC, τ = 40 ms) | |
42 W (N/O contact, 110 V DC, τ = 40 ms) | |
42 W (N/O contact, 220 V DC, τ = 40 ms) | |
Switching capacity | min. 50 mW |
Mechanical service life | 10x 106cycles |
Switching capacity (360/h cycles) | 4 A (24 V (DC13)) |
4 A (250 V (AC15)) | |
Switching capacity according to IEC 60947-5-1 | 3 A (24 V (DC13)) |
3 A (250 V (AC15)) | |
Output fuse | 10 A gL/gG (N/O contact) |
4 A gL/gG (N/O contact, for low-demand applications) | |
6 A gL/gG (N/C contact) |
Relay type | Electromechanical relay with forcibly guided contacts in accordance with EN 50205 |
---|---|
Nominal operating mode | 100% operating factor |
Net weight | 137.48 g |
Mounting position | vertical or horizontal |
Mounting type | DIN rail mounting |
Degree of protection | IP20 |
IP54 | |
Min. degree of protection of inst. location | IP54 |
Housing material | PBT |
Housing color | yellow |
Connection method | Spring-cage connection |
---|---|
pluggable | Yes |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Stop category | 0 |
---|---|
Designation | IEC 61508 - High demand |
Safety Integrity Level (SIL) | 1 |
Designation | IEC 61508 - Low demand |
Safety Integrity Level (SIL) | 1 |
Designation | EN ISO 13849 |
Performance level (PL) | c |
Category | 1 |
Safety Integrity Level Claim Limit (SIL CL) | 1 |
Designation | Air clearances and creepage distances between the power circuits |
---|---|
Standards/regulations | DIN EN 50178 |
Rated insulation voltage | 250 V |
250 V | |
Rated surge voltage/insulation | Safe isolation 4 kV between all current paths and housing |
Degree of pollution | 2 |
Overvoltage category | II |
Shock | 15g (In the event of stress caused by shock, contact reactions are possible for up to 2 ms.) |
Vibration (operation) | 10 Hz ... 150 Hz, 2g (In the event of stress caused by vibration, contact reactions are possible for up to 1 ms.) |
Conformance | CE-compliant |
China RoHS | Environmentally friendly use period: unlimited = EFUP-e |
---|---|
No hazardous substances above threshold values |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2963970-PSR-SPP- 24UC/URM/5X1/2X2 | 127 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.