Safety digital output module, IP20 degree of protection, for the SafetyBridge-, INTERBUS-Safety- and the PROFIsafe system. It has four safe digital outputs which include one positive and one negative switching output each depending on the parameterization.

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The safety module is an output module from the Inline product range, designed for use in an INTERBUS-Safety or PROFIsafe system. The safety module can be used as part of an Inline station at any point within an INTERBUS-Safety or PROFIsafe Inline system. The transmission speed of the safety module can be set to 500 kbaud or 2 Mbaud using a switch. Only one transmission speed must be used uniformly within a station.

The module has 4 safe digital outputs which includes one positive and one negative switching output depending on the parameterization. The outputs can be parameterized according to the application and enable the integration of actuators in the safe INTERBUS system (INTERBUS-Safety) and in the PROFIsafe system. Depending on the installation and parameterization, in these systems the safety module can achieve the following safety integrity:

– Up to category 4 according to standard EN 954-1

– Up to SIL 3 according to standards EN 61508 and EN 62061

– Up to PL e according to standard EN ISO 13849-1

Dimensions

Width48.8 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Permissible humidity (storage/transport)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Air pressure (operation)80 kPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above mean sea level)
Degree of protectionIP20

Interfaces

Fieldbus systemINTERBUS
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s / 2 MBit/s (can be switched)

Digital outputs

Output nameDigital outputs
Output description+/- switching
Connection methodSpring-cage connection
2, 3, 4-wire
Number of outputs4 (for two-channel assignment, +/- switching)
4
Protective circuitOverload protection, short-circuit protection of outputs
Output voltage24 V DC (US - 1 V)
Nominal output voltage24 V DC
Output currentmax. 3 A (Total current of all outputs)
Maximum output current per channel2 A
Maximum output current per module3 A (See technical data)

Power supply for module electronics

Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC
Communications power UL7.5 V (via voltage jumper)
Current consumptionmax. 230 mA (from the local bus)

General

Net weight247.7 g
Note on weight specificationswith connectors
Mounting typeDIN rail
Category according to EN 13849-14
Diagnostics messagesShort-circuit / overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor

Inline potentials

Communications power UL7.5 V DC (see safety data)
Current consumption from ULmax. 230 mA
Main circuit supply UM24 V DC
Supply voltage range UM19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumption from UMtyp. 30 mA (all outputs set including actuator current)
max. 3.03 A
Segment supply voltage US24 V

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2916493-IB IL 24 PSDO 4/4-PACEnglish111 KbytesPHOENIX CONTACT-2916493-IB IL 24 PSDO 4/4-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or