quot4 in 1quot three-phase semiconductor reversing contactor with - PHOENIX CONTACT - ELR W3-230AC/500AC- 9I - 2297060 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

quot4 in 1quot three-phase semiconductor reversing contactor with - PHOENIX CONTACT - ELR W3-230AC/500AC- 9I - 2297060

ELR W3-230AC/500AC- 9I




Ship on today

"4 in 1" three-phase semiconductor reversing contactor with 230 V AC input, 9 A output current, emergency stop function, and adjustable overload switching.

More details



* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

Price: $158.64
*This price is per unit and is the net value (not including taxes if applicable).
Up to 35% discount for registered clients.

Request a quote
How it Works

How does the quotation request work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with our price proposals
4 You can directly process the order for the quotation

There are several options for payment
- Credit card
- Wire Transfer
- PayPal

More info

Input data

Input nameDevice supply
Mains frequency40 Hz
100 Hz
Rated control circuit supply voltage US230 V AC
Voltage range with reference to US0.4 ... 1.1
Rated control supply current IS4 mA
Rated actuating voltage UC230 V AC
Voltage range with reference to UC0.4 ... 1.1
Rated actuating current IC7 mA
Protective circuitSurge protection
Typical response time< 35 ms
Typical turn-off time< 80 ms
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED
Input nameControl input right/left
Switching threshold44 V AC (“0” signal)
85 V AC (“1” signal)

Output data load output

Nominal output voltage500 V AC
Nominal output voltage range42 V AC ... 550 V AC
Load current range1.5 A ... 9 A (see to derating)
Rated operating current at AC-519 A
Rated operating current at AC-53a6.5 A
Leakage current0 mA
Residual voltage< 0.5 V
Surge current100 A (t = 10 ms)
Protective circuitSurge protection

Output data reply output

NoteConfirmation 01: Floating PDT contact

Measuring technology and signaling contact

Measuring viaCurrent transformer for line current on L1 and L3
Current range1 A ... 45 A

Connection data, control circuit

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14


Test voltage input/output4 kVrms
Mounting positionVertical (horizontal DIN rail)
Assembly instructionsCan be aligned with spacing = 20 mm
Operating mode100% operating factor
Standards/regulationsDIN EN 50178
EN 60947
DesignationPower station requirements
Standards/regulationsDWR 1300 / ZXX01/DD/7080.8d
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178
Insulationsafe isolation
Pollution degree2
Overvoltage categoryIII
Reversing frequency≤ 2 Hz


Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Degree of protectionIP20

PDF of quot4 in 1quot three-phase semiconductor reversing contactor with - PHOENIX CONTACT - ELR W3-230AC/500AC- 9I - 2297060

PHOENIX CONTACT-2297060-ELR W3-230AC/500AC- 9IEnglish100 KbytesPHOENIX CONTACT-2297060-ELR W3-230AC/500AC- 9I

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait

* Required fields