F-MS-T1/T2 50 ST 2800191 PHOENIX CONTACT N-PE replacement plug for VAL-MS-T1/T2 335/12.5 plug-in lighting/su.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

F-MS-T1/T2 50 ST 2800191 PHOENIX CONTACT N-PE replacement plug for VAL-MS-T1/T2 335/12.5 plug-in lighting/su..

F-MS-T1/T2 50 ST

2800191

PHOENIX_CONTACT

10

Available

Ship on today

N-PE replacement plug for VAL-MS-T1/T2 335/12.5 plug-in lighting/surge arrester.

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height47 mm
Width17.7 mm
Depth67.3 mm
Horizontal pitch1 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC power supply systemTT
TN-S
Housing materialPA 6.6
PBT
Flammability rating according to UL 94V-0
Colorjet black RAL 9005
Standards for cearances and creepage distancesDIN EN 60664-1
EN 61643-11
Mounting typeOn base element
TypeDIN rail module, two-section, divisible
Surge protection fault messageoptical
Direction of actionN-PE

Protective circuit

IEC test classificationI / II
T1 / T2
T1
EN typeT1 / T2
T1
Lightning protection classIII / IV
Nominal voltage UN240/415 V AC (TN-S)
Maximum continuous operating voltage UC264 V AC
Nominal frequency fN50 Hz (60 Hz)
Residual current IPE≤ 5 µA
Standby power consumption PC≤ 1.3 mVA
Max. discharge current Imax (8/20) µs50 kA
Nominal discharge current In (8/20) µs50 kA
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.7 kV
Voltage protection level Up≤ 1.7 kV
Response time tA≤ 100 ns
Follow current interrupt rating Ifi100 A (264 V AC)

Connection, protective circuit

Connection type INFLASHTRAB/VALVETRAB plug-in system
Connection type OUTFLASHTRAB/VALVETRAB plug-in system

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2800191-F-MS-T1/T2 50 STEnglish119 KbytesPHOENIX CONTACT-2800191-F-MS-T1/T2 50 ST

Reviews (0)