MACX MCR-SL-RPSSI-I-UP-SP 2924210 PHOENIX CONTACT Repeater power supply for supplying 2 and 3-conductor tran.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-SL-RPSSI-I-UP-SP 2924210 PHOENIX CONTACT Repeater power supply for supplying 2 and 3-conductor tran..

MACX MCR-SL-RPSSI-I-UP-SP

2924210

PHOENIX_CONTACT

Available

Ship on today

Repeater power supply for supplying 2 and 3-conductor transmitters with HART transmission and wide range power supply, SIL, spring-cage connection

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$240.75
2+$235.06
3+$232.24
4+$231.51
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width17.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Degree of protectionIP20

Input data

Signal inputRepeater power supply operation
Current input signal4 mA ... 20 mA
Transmitter supply voltage> 16 V (20 mA)
> 15.3 V (22.5 mA)
Signal inputSignal conditioner operation
Current input signal0 mA ... 20 mA
4 mA ... 20 mA

Output data

Signal outputRepeater power supply operation
Voltage output signal1 V ... 5 V (internal resistance, 250 Ω, 0.1%)
Current output signal4 mA ... 20 mA (active)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 600 Ω (20 mA)
< 525 Ω (22.5 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 22.5 mA (Cable short-circuit in the input)
Signal outputSignal conditioner operation
Voltage output signal0 V ... 5 V (internal resistance, 250 Ω, 0.1%)
Current output signal0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Load/output load current output< 600 Ω (20 mA)
< 525 Ω (22.5 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)

Power supply

DesignationRepeater power supply operation
Supply voltage range24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Max. current consumption< 80 mA (24 V DC / 20 mA)
Power consumption< 1.6 W (24 V DC / 20 mA)
< 1.9 W

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Connection methodPush-in connection

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Step response (10-90%)< 600 µs (for 4 mA ... 20 mA step)
Status displayGreen LED (supply voltage)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Emitted interferenceEN 61000-6-4
Housing materialPA 66-FR
Colorgreen
DesignationInput/output/power supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
ConformanceCE-compliant, additionally EN 61326-1
ATEXEx II 3 G Ex nA IIC T4 Gc X
UL, USA / CanadaUL 508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
Functional Safety (SIL)SIL 2

Data communication (bypass)

HART functionYes
Protocols supportedHART

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2924210-MACX MCR-SL-RPSSI-I-UP-SPEnglish161 KbytesPHOENIX CONTACT-2924210-MACX MCR-SL-RPSSI-I-UP-SP