Orderkey | 2866527 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 211 (C-6-2015) |
GTIN | 4046356562973 |
Weight per Piece (excluding packing) | 370.000 g |
Custom tariff number | 85049091 |
Country of origin | CN (China) |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 70 °C (> 55° C derating : 2.5%/K) |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Nominal input voltage range | 48 V DC |
---|---|
Input voltage range | 30 V DC ... 56 V DC |
Nominal input current | 2x 10 A (-25 °C ... 55 °C) |
1x 20 A (-25 °C ... 55 °C) | |
Maximum input current | 2x 15 A (-25°C ... 40°C) |
1x 30 A (-25°C ... 40°C) |
Nominal output voltage | 47.3 V DC (Input/output voltage drop of 48 V ... 0.7 V ) |
---|---|
Nominal output current (IN) | 20 A (Increasing power) |
10 A (Redundancy) | |
Derating | 55 °C ... 70 °C (2.5%/K) |
Connection in series | No |
Maximum power dissipation in no-load condition | 7 W (IOUT= 10 A) |
Power loss nominal load max. | 14 W (IOUT= 20 A) |
Net weight | 0.37 kg |
---|---|
Efficiency | > 97 % |
Protection class | III |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | |
> 10000000 h (40 °C) | |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: horizontally 0 mm, vertically 50 mm |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Stripping length | 9 mm |
Screw thread | M2,5 |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 10 |
Stripping length | 14 mm |
Screw thread | M3 |
Conductor cross section solid min. | 0.2 mm² |
---|---|
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 14 |
Screw thread | M2,5 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Connection in acc. with standard | CUL |
Standards/regulations | EN 61000-4-2 |
Contact discharge | 4 kV (Test Level 2) |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency range | 1.4 GHz ... 2 GHz |
Test field strength | 3 V/m (Test Level 2) |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-6-3 |
EN 61000-4-6 | |
Frequency range | 0.15 MHz ... 80 MHz |
Voltage | 10 V (Test Level 3) |
Low Voltage Directive | Conformance with LV directive 2006/95/EC |
Standard - Electrical safety | EN 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
UL approvals | UL/C-UL listed UL 508 |
UL/C-UL Recognized UL 60950-1 | |
Shock | 15g in all directions in acc. with IEC 60068-2-27 |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm |
15 Hz ... 150 Hz, 2.3g tv= 90 min. |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2866527-TRIO-DIODE/48DC/2X10/1X20 | 120 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.