Rail-mountable surge arrester for higher signal voltages. Protectiv - PHOENIX CONTACT - PT 2X1-VF-120AC - 2859327 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

Rail-mountable surge arrester for higher signal voltages. Protectiv - PHOENIX CONTACT - PT 2X1-VF-120AC - 2859327

PT 2X1-VF-120AC





Ship on today

Rail-mountable surge arrester for higher signal voltages. Protective circuit free of leakage current for two floating signals.Nominal voltage: 120 V AC

More details

Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

Price: $90.05
*This price is per unit and is the net value (not including taxes if applicable).
Up to 35% discount for registered clients.

Request a quote
How it Works

How does the quotation request work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with our price proposals
4 You can directly process the order for the quotation

There are several options for payment
- Credit card
- Wire Transfer
- PayPal

More info


Height90 mm
Width17.7 mm
Depth65.5 mm
Horizontal pitch1 Div.
Complete module height90 mm
Complete module width17.7 mm
Complete module depth65.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 80 °C
Degree of protectionIP20


Housing materialPA 6.6
Flammability rating according to UL 94V0
Standards for cearances and creepage distancesIEC 60664-1
DIN VDE 0110-1
Overvoltage categoryIII
Pollution degree2
Mounting typeDIN rail: 35 mm
TypeDIN rail module, two-section, divisible
Number of positions2
Direction of actionLine-Line & Line-Earth Ground
Arrester can be tested with CHECKMASTER from software version:SW Version 2.13 or later

Protective circuit

IEC test classificationC1
Nominal voltage UN120 V AC
Maximum continuous voltage UC175 V AC
Nominal current IN6 A
Operating effective current IC at UC≤ 2 µA
Residual current IPE≤ 4 µA
Nominal discharge current In (8/20) µs3 kA
Nominal discharge current In (8/20) µs (Core-Earth)3 kA
Total surge current (8/20) µs8 kA
Max. discharge current Imax (8/20) µs8 kA
Nominal pulse current Ian (10/1000) µs (Core-Earth)40 A
Impulse discharge current (10/350)˽µs, peak value limp300 A
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 800 V
Residual voltage at In (conductor-ground)≤ 600 V
Residual voltage with Ian (10/1000)µs (conductor-ground)≤ 360 V
Energy absorption85 J
Voltage protection level Up≤ 1 kV (C2 - 2 kA)
Voltage protection level Up (core-ground)≤ 900 V (C1 - 500 A)
≤ 950 V (C2 - 1 kA)
≤ 1 kV (C3 - 25 A)
≤ 1.1 kV (Iimp-300 A)
Response time tA≤ 100 ns
Capacitytyp. 3 pF
Resistance in series0 Ω
Surge protection fault messageNone
Max. required back-up fuse6 A (e.g. D01 gL/gG)
Impulse durability (conductor-ground)C1 - 1 kV/500 A
C2 - 4 kV/2 kA
C3 (25 A)

Connection data

Connection methodScrew connection
Connection type INScrew terminal blocks
Connection type OUTScrew terminal blocks
Screw threadM3
Tightening torque0.8 Nm
Stripping length8 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12

Connection, equipotential bonding

Connection methodScrew connection
Tightening torque, min0.8 Nm

Standards and Regulations

Standards/regulationsEN 61643-21
IEC 61643-21

PDF of Rail-mountable surge arrester for higher signal voltages. Protectiv - PHOENIX CONTACT - PT 2X1-VF-120AC - 2859327

PHOENIX CONTACT-2859327-PT 2X1-VF-120ACEnglish72 KbytesPHOENIX CONTACT-2859327-PT 2X1-VF-120AC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait

* Required fields