PT 5-HF-12 DC-ST 2838775 PHOENIX CONTACT Protective plug PT with HF protective circuit for 4 signal wires. N.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PT 5-HF-12 DC-ST 2838775 PHOENIX CONTACT Protective plug PT with HF protective circuit for 4 signal wires. N..

PT 5-HF-12 DC-ST

2838775

PHOENIX_CONTACT

10

Available

Ship on today

Protective plug PT with HF protective circuit for 4 signal wires. Nominal voltage: 12 V DC

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height45 mm
Width17.7 mm
Depth52 mm
Horizontal pitch1 Div.
Complete module height90 mm
Complete module width17.7 mm
Complete module depth65.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA
Flammability rating according to UL 94V0
Colorblack
Standards for cearances and creepage distancesDIN EN 61664-1
IEC 60664-1
Overvoltage categoryIII
Pollution degree2
Mounting typeOn base element
TypeDIN rail module, two-section, divisible
Number of positions5
Direction of actionLine-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
Arrester can be tested with CHECKMASTER from software version:From SW rev. 1.10

Protective circuit

IEC test classificationC1
C2
C3
D1
VDE requirement classC1
C2
C3
D1
Nominal voltage UN12 V DC
Maximum continuous voltage UC14 V DC
9.8 V AC
Maximum continuous voltage UC (wire-wire)14 V DC
9.8 V AC
Maximum continuous voltage UC (wire-ground)14 V DC (with PT 2x2-BE)
Nominal current IN450 mA (45°C)
Operating effective current IC at UC≤ 5 µA
Residual current IPE≤ 5 µA (with PT 2x2-BE)
≤ 1 µA (with PT 2x2+F-BE)
Nominal discharge current In (8/20) µs (Core-Core)10 kA
Nominal discharge current In (8/20) µs (Core-Earth)10 kA
Nominal discharge current In (8/20) µs (Core-GND)10 kA
Total surge current (8/20) µs20 kA
Max. discharge current Imax (8/20) µs maximum (Core-Core)10 kA
Max. discharge current Imax (8/20) µs maximum (Core-Earth)10 kA
Nominal pulse current Ian (10/1000) µs (Core-Core)67 A
Impulse discharge current (10/350)˽µs, peak value limp2.5 kA
Output voltage limitation at 1 kV/µs (Core-Core) spike≤ 55 V
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 55 V (PT 2x2-BE)
≤ 700 V (with PT 2x2+F-BE)
Output voltage limitation at 1 kV/µs (Core-Core) static≤ 25 V
Output voltage limitation at 1 kV/µs (Core-Earth) static≤ 25 V
≤ 40 V (PT 2x2+F-BE)
Residual voltage at In (conductor-conductor)≤ 25 V
Residual voltage at In (conductor-ground)≤ 40 V (with PT 2x2-BE)
Residual voltage at In (conductor-GND)≤ 25 V (with PT 2x2-BE)
Residual voltage with Ian (10/1000)µs (conductor-conductor)≤ 25 V
Residual voltage with Ian (10/1000)µs (conductor-GND)≤ 25 V
Voltage protection level Up (core-core)≤ 80 V (C1 - 1 kV/500 A)
≤ 50 V (C3 - 25 A)
≤ 100 V (C2 - 10 kV/5 kA)
≤ 80 V (6 kV/3 kA)
Voltage protection level Up (core-ground)≤ 85 V (C1 - 1 kV/500 A)
≤ 140 V (C2 - 10 kV/5 kA)
≤ 100 V (6 kV/3 kA)
≤ 50 V (C3 - 25 A)
Voltage protection level Up (core-GND)≤ 50 V (C3 - 25 A)
Response time tA (Core-Core)≤ 500 ns
Response time tA (Core-Earth)≤ 500 ns
Input attenuation aE, sym.typ. 0.3 dB (≤ 5 MHz / 100 Ω)
Cut-off frequency fg (3 dB), sym. in 100 Ohm systemtyp. 60 MHz
Capacity (Core-Core)typ. 30 pF
Resistance in series2.2 Ω ±10 % (1-2/5-6/7-8/11-12)
Surge protection fault messageNone
Max. required back-up fuse500 mA (e.g. T in acc. with IEC 127-2/III)
Impulse durability (conductor-conductor)C2 - 10 kV/5 kA
C3 (67 A)
Impulse durability (conductor-ground)C2 - 10 kV/5 kA
C3 (67 A)
D1 - 2,5 kA

Connection data

Connection methodScrew connection (in connection with the base element)
Connection type INPLUGTRAB plug-in system
Connection type OUTPLUGTRAB plug-in system
Screw threadM3
Tightening torque0.8 Nm
Stripping length8 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12

Connection, equipotential bonding

Stripping length8 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2838775-PT 5-HF-12 DC-STEnglish237 KbytesPHOENIX CONTACT-2838775-PT 5-HF-12 DC-ST

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email