MACX PL-EX-T-UIREL-UP 2904910 PHOENIX CONTACT Programmable temperature transducer with analog output and 3 l.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX PL-EX-T-UIREL-UP 2904910 PHOENIX CONTACT Programmable temperature transducer with analog output and 3 l..

MACX PL-EX-T-UIREL-UP

2904910

PHOENIX_CONTACT

Available

Ship on today

Programmable temperature transducer with analog output and 3 limit value relays, intrinsically safe signal inputs, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, electrical isolation, wide-range power supply, screw connection, PLd

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$469.26
2+$462.15
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width35 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)typ. 5 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Shock15g, according to IEC 60068-2-27
Vibration (operation)5g, accordance to IEC 60068-2-6
Degree of protectionIP20

Input data

Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Temperature measuring range-200 °C ... 850 °C
Input signal range0 Ω ... 50 kΩ
Potentiometer resistance range0 Ω ... 50 kΩ
Input signal range-1000 mV ... 1000 mV

Output data

Current output signal4 mA ... 20 mA
Max. current output signal22 mA
Load/output load current output≤ 600 Ω (20 mA)
Behavior in the event of a sensor erroraccording to NE 43 or freely configurable
Output nameRelay output
Output description1 SIL/PL
Contact type2 PDT
Contact materialAgSnO2, hard gold-plated
Maximum switching voltage250 V AC (250 V DC)
Maximum inrush current2 A (250 V AC)
2 A (28 V DC)
0.2 A (120 V DC)
Mechanical service life1 x 105 cycles

Power supply

Supply voltage range24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Typical current consumption< 100 mA (24 V DC)
Power consumption< 2.4 W

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

Maximum transmission error0.1 % (e.g. for Pt 100, 300 K span, 4 ... 20 mA)
Maximum temperature coefficient0.01 %/K
Step response (0–99%)typ. 1000 ms (With SIL)
typ. 700 ms (Without SIL)
Status displayGreen LED (supply voltage, PWR)
Red LED, flashing (line, sensor error, ERR)
Red LED (module error, ERR)
Yellow LED (switching output)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Housing materialPA 66-FR
Coloryellow
DesignationInput/output/power supply
Electrical isolation2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/switching output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationOutput/supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
ConformanceCE-compliant
ATEXEx II (1) G [Ex ia Ga] IIC
Ex II (1) D [Ex ia Da] IIIC
Ex II 3 G Ex nA nC ic IIC T4 Gc X
IECEx[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA nC ic IIC T4 Gc X
UL, USA / CanadaUL 508 Listed
Functional Safety (SIL)SIL 2

Safety data

Max. internal inductance Linegligible
Max. internal capacitance Ci44 nF
Max. output voltage Uo6 V
Max. output current Io7.4 mA
Max. output power Po11 mW
GroupIIC
Max. external inductivity Lo100 mH
Max. external capacity Co1.3 µF
GroupIIC
Max. external inductivity Lo10 mH
Max. external capacity Co1.7 µF
GroupIIC
Max. external inductivity Lo1 mH
Max. external capacity Co2.6 µF
GroupIIC
Max. external inductivity Lo0 mH
Max. external capacity Co10 µF
GroupIIB
Max. external inductivity Lo100 mH
Max. external capacity Co6.8 µF
GroupIIB
Max. external inductivity Lo10 mH
Max. external capacity Co9.2 µF
Safety-related maximum voltage Um253 V AC/DC

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value2 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value2 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value2 %

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2904910-MACX PL-EX-T-UIREL-UPEnglish140 KbytesPHOENIX CONTACT-2904910-MACX PL-EX-T-UIREL-UP

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or