10

Available

Ship on today

Pre-assembled relay module with push-in connection, consisting of: relay base, power contact relay, plug-in display/suppressor module, and retaining bracket. Contact type: 1 PDT. Input voltage: 230 V AC

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+$10.86
20+$10.54
40+$10.28
60+$10.16
80+$10.08
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width16 mm
Height93 mm
Depth75 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 50 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN230 V AC
Input voltage range in reference to UNsee diagram
Mains frequency50 Hz
60 Hz
Typical input current at UN6 mA
Typical response time3 ms ... 12 ms
Typical release time range3 ms ... 20 ms
Coil voltage230 V AC
Protective circuitVaristor
Operating voltage displayYellow LED

Contact side

Contact type1 PDT
Contact materialAgNi
Maximum switching voltage250 V AC/DC
Minimum switching voltage12 V (at 10 mA)
Min. switching current10 mA (at 12 V)
Maximum inrush current25 A (20 ms, N/O contact)
Limiting continuous current10 A (see diagram)
Interrupting rating (ohmic load) max.240 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
2500 VA (for 250 V AC)
Switching capacity in acc. with DIN VDE 0660/IEC 609472 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
6 A (at 24 V, AC15)
6 A (at 120 V, AC15)
6 A (at 250 V, AC15)

Connection data input side

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1.5 mm² (Ferrules without plastic sleeve)
Conductor cross section AWG26 ... 16

General

Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)
Test voltage relay winding/relay contact4 kVrms (50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionIP20 (Relay socket)
RT III (Relay)
Mechanical service lifeApprox. 107 cycles
Standards/regulationsDIN EN 50178
IEC 62103
Rated insulation voltage250 V AC
Pollution degree2
Overvoltage categoryIII
Mounting positionany
Assembly instructionsIn rows with zero spacing

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2903339-RIF-1-RPT-LV-230AC/1X21English162 KbytesPHOENIX CONTACT-2903339-RIF-1-RPT-LV-230AC/1X21

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or