RIF-1-RPT-LV-120AC/2X21AU 2903328 PHOENIX CONTACT Relay Module View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RIF-1-RPT-LV-120AC/2X21AU 2903328 PHOENIX CONTACT Relay Module

RIF-1-RPT-LV-120AC/2X21AU

2903328

PHOENIX_CONTACT

10

Relay Module

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
10+$18.21
20+$15.81
30+$15.26
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2903328
Packing unit10 pc
Minimum order quantity10 pc
Catalog pagePage 341 (C-5-2017)
GTIN4046356732321
Weight per Piece (excluding packing)68.100 g
Custom tariff number85364900
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area
Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)

Dimensions

Width16 mm
Height93 mm
Depth75 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 50 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN120 V AC
Input voltage range in reference to UNsee diagram
Mains frequency50/60 Hz
Typical input current at UN8 mA
Typical response time3 ms ... 12 ms
Typical release time range3 ms ... 20 ms
Coil voltage120 V AC
Protective circuitVaristor
Operating voltage displayYellow LED
Power dissipation for nominal condition0.96 W

Contact side

Contact type2 PDT
Type of switch contactSingle contact
Contact materialAgNi, hard gold-plated
Maximum switching voltage30 V AC
36 V DC
Minimum switching voltage100 mV (at 10 mA)
Min. switching current1 mA (at 24 V)
Maximum inrush current50 mA
Limiting continuous current50 mA
Interrupting rating (ohmic load) max.1.2 W (at 24 V DC)

Contact side (with destroyed gold layer)

Contact materialAgNi
Notethe following values are applicable if a gold layer is destroyed
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V (at 10 mA)
Limiting continuous current12 A (20 ms, N/O contact)
Min. switching current10 mA (At 5 V)
Interrupting rating (ohmic load) max.192 W (at 24 V DC)
96 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
57 W (at 220 V DC)
2000 VA (for 250 V AC)
Switching capacity2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
2 A (at 24 V, AC15)
2 A (at 120 V, AC15)
2 A (at 250 V, AC15)

Connection data 1

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

Connection data 2

Connection nameContact side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section flexible0.14 mm² ... 1.5 mm²
0.14 mm² ... 1.5 mm² (Ferrule with plastic sleeve)
0.14 mm² ... 1 mm² (Ferrule with plastic sleeve, two conductors on double terminal block)
Conductor cross section AWG26 ... 16 (solid)
26 ... 16 (flexible)

General

Type of noteNotes on operation
NoteFBS 2-6... plug-in bridge for the input side (A2) and FBS-2-8... plug-in bridge for the output side (11/21)
Test voltage relay winding/relay contact4 kVrms(50 Hz, 1 min.)
Test voltage PDT/PDT2.5 kVrms(50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionIP20 (Relay base)
RT III (Relay)
Mechanical service lifeapprox. 107cycles
Service life, electricalsee diagram
Mounting positionany
Assembly instructionsIn rows with zero spacing
Net weight (SAP)68.1 g

Standards and Regulations

Standards/regulationsDIN EN 50178
Rated surge voltage6 kV
InsulationSafe isolation, basic insulation, and 4 kV rated surge voltage between all changeover contacts.
Degree of pollution2
Overvoltage categoryIII
Flammability rating according to UL 94V2

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Articles in set

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.