TRIO-PS/1AC/12DC/10 2866488 PHOENIX CONTACT Power supply unit View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

TRIO-PS/1AC/12DC/10 2866488 PHOENIX CONTACT Power supply unit

TRIO-PS/1AC/12DC/10

2866488

PHOENIX_CONTACT

Power supply unit

More details


Power Supplies (PS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $239.40
Unit price: $239.40

Quantity Price
1+$239.40
2+$217.79
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2866488
Packing unit1 pc
Catalog pagePage 173 (C-6-2015)
GTIN4046356287807
Weight per Piece (excluding packing)792.400 g
Custom tariff number85044030
Country of originCN (China)

Dimensions

Width40 mm
Height130 mm
Depth115 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 55° C derating : 2.5%/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)
Climatic class3K3 (in acc. with EN 60721)
Degree of pollution2

Input data

Nominal input voltage range100 V AC ... 240 V AC
Input voltage range85 V AC ... 264 V AC (derating < 90 V AC: 2.5 % per Kelvin)
Dielectric strength maximum300 V AC
AC frequency range45 Hz ... 65 Hz
Discharge current to PE< 3.5 mA
Current consumption1.7 A (120 V AC)
0.9 A (230 V AC)
Nominal power consumption218.7 VA
Inrush surge current< 15 A
Mains buffering> 20 ms (120 V AC)
> 86 ms (230 V AC)
Choice of suitable circuit breakers6 A ... 16 A (Characteristics B, C, D, K)
Power factor (cos phi)0.63
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage12 V DC ±1 %
Setting range of the output voltage (USet)10 V DC ... 18 V DC (> 12 V DC, constant capacity restricted)
Nominal output current (IN)10 A (-25 °C ... 55 °C)
Derating55 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesyes
Feedback resistance25 V DC
Output overvoltage protection< 25 V DC
Max. capacitive loadunlimited
Active current limitationApprox. 12 A (in the event of a short-circuit)
Control deviation< 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Residual ripple< 20 mVPP
Output power120 W
Typical response time< 1 s
Peak switching voltages nominal load< 70 mVPP
Maximum power dissipation in no-load condition1.1 W
Power loss nominal load max.18 W

General

Net weight0.6 kg
Operating voltage displayGreen LED
Efficiency> 86 % (for 230 V AC and nominal values)
Insulation voltage input/output4 kV AC (type test)
2 kV AC (routine test)
Insulation voltage input / PE2 kV AC (type test)
2 kV AC (routine test)
Insulation voltage output / PE500 V DC (type test)
Protection classI (with PE connection)
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)
> 1871000 h (40 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length9 mm
Screw threadM2,5

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length9 mm
Screw threadM2,5

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge4 kV (Test Level 2)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 1 GHz
Test field strength10 V/m
Frequency range1.4 GHz ... 2 GHz
Test field strength3 V/m
Standards/regulationsEN 61000-4-4
CommentsCriterion B
Standards/regulationsEN 61000-6-3
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz
Voltage10 V (Test Level 3)
Standards/regulationsEN 61000-4-11
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
EN 61558-2-17
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltageEN 60950-1 (SELV)
EN 60204 (PELV)
Standard - Safe isolationDIN VDE 0100-410
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipmentEN 50178
Standard – Limitation of mains harmonic currentsEN 61000-3-2
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
Shock15g in all directions in acc. with IEC 60068-2-27
Vibration (operation)< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Rail applicationsEN 50121-4

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.