QUINT-PS-3X400-500AC/48DC/10 2938219 PHOENIX CONTACT DIN rail power supply, 48 V DC/10 A, primary-switched, .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

QUINT-PS-3X400-500AC/48DC/10 2938219 PHOENIX CONTACT DIN rail power supply, 48 V DC/10 A, primary-switched, ..

QUINT-PS-3X400-500AC/48DC/10

2938219

PHOENIX_CONTACT

Available

Ship on today

DIN rail power supply, 48 V DC/10 A, primary-switched, 3-phase

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$493.02
2+$486.19
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width160 mm
Height130 mm
Depth125 mm
Width with alternative assembly122 mm
Height with alternative assembly130 mm
Depth with alternative assembly163 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)95 % (at 25 °C, non-condensing)
Noise immunityEN 61000-6-2:2005

Input data

Nominal input voltage range3x 400 V AC ... 500 V AC
Input voltage range3x 320 V AC ... 575 V AC (for all three phases)
450 V DC ... 800 V DC (for all three phases)
AC frequency range45 Hz ... 65 Hz
Frequency range DC0 Hz
Nominal power consumption480 W
Inrush surge current< 10 A
Power failure bypass> 25 ms (400 V AC)
> 30 ms (480 V AC)
Choice of suitable circuit breakers3x 6 A ... 16 A (Characteristics B, C, D, K)
Type of protectionTransient surge protection
Protective circuit/componentVaristor

Output data

Nominal output voltage48 V DC ±1 %
Setting range of the output voltage30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted)
Nominal output current10 A (-25 °C ... 60 °C)
POWER BOOST13 A (-25°C ... 40°C permanent )
Derating60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for redundancy and increased capacity
Connection in seriesYes
Residual ripple< 20 mVPP
Output power480 W
Typical response time< 1 s
Peak switching voltages nominal load< 140 mVPP (20 MHz)
Maximum power dissipation in no-load condition10 W
Power loss nominal load max.45 W

General

Net weight2.3 kg
Efficiency> 90 % (for 230 V AC and nominal values)
Insulation voltage input/output3 kV (type test)
1.5 kV (routine test)
Protection classI (with PE connection)
MTBF (IEC 61709, SN 29500)> 500000 h
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsCan be aligned: Horizontally 0 mm, vertically 50 mm

Connection data, input

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.10
Stripping length8 mm
Screw threadM3

Connection data, output

Connection methodScrew connection
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Stripping length10 mm
Screw threadM4

Signaling

Output nameDC OK active
Output descriptionUOUT > 0.9 x UN: High signal
Maximum switching voltage≤ 24 V
Output voltage+ 24 V DC
Maximum inrush current≤ 20 mA
Continuous load current≤ 20 mA
Status display"DC OK" LED green
Note on status displayUOUT < 0.9 x UN: LED flashing
Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.10 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Screw threadM4
Output nameDC OK floating
Output descriptionRelay contact, UOUT > 0.9 x UN: Contact closed
Maximum switching voltage≤ 30 V AC/DC
Maximum inrush currentmax. 0.5 A
Continuous load current≤ 1 A
Status display"DC OK" LED green
Note on status displayUOUT < 0.9 x UN: LED flashing

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2938219-QUINT-PS-3X400-500AC/48DC/10English136 KbytesPHOENIX CONTACT-2938219-QUINT-PS-3X400-500AC/48DC/10

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or