Power supply unit
Power Supplies (PS)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2320827 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 214 (C-4-2017) |
GTIN | 4046356547734 |
Weight per Piece (excluding packing) | 2,500.000 g |
Custom tariff number | 85044030 |
Country of origin | TH (Thailand) |
Width | 96 mm |
---|---|
Height | 130 mm |
Depth | 179 mm |
Width with alternative assembly | 176 mm |
Height with alternative assembly | 130 mm |
Depth with alternative assembly | 99 mm |
Degree of protection | IP20 |
---|---|
Ambient temperature (operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) | -40 °C |
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic class | 3K3 (in acc. with EN 60721) |
Degree of pollution | 2 |
Installation height | 4000 m |
Nominal input voltage range | 3x 400 V AC ... 500 V AC |
---|---|
Input voltage range | 3x 320 V AC ... 575 V AC |
2x 360 V AC ... 575 V AC (Not approved by UL) | |
450 V DC ... 800 V DC | |
AC frequency range | 45 Hz ... 65 Hz |
Frequency range DC | 0 Hz |
Discharge current to PE | < 3.5 mA |
Current consumption | 3x 2.1 A (400 V AC) |
3x 1.7 A (500 V AC) | |
1.7 A (600 V DC) | |
Nominal power consumption | 1386 VA |
Inrush surge current | < 20 A (typical) |
Mains buffering | typ. 25 ms (400 V AC) |
typ. 35 ms (500 V AC) | |
Choice of suitable circuit breakers | 6 A ... 16 A (AC: Characteristics B, C, D, K) |
Type of protection | Transient surge protection |
Protective circuit/component | Varistor |
Nominal output voltage | 48 V DC ±1 % |
---|---|
Setting range of the output voltage (USet) | 30 V DC ... 56 V DC (> 48 V DC, constant capacity restricted) |
Nominal output current (IN) | 20 A (-25 °C ... 60 °C, UOUT= 48 V DC) |
POWER BOOST (IBoost) | 22.5 A (-25°C ... 40°C permanent, UOUT= 48 V DC ) |
Selective Fuse Breaking (ISFB) | 100 A (12 ms) |
Derating | 60 °C ... 70 °C (2.5%/K) |
Connection in parallel | Yes, for redundancy and increased capacity |
Connection in series | yes |
Feedback resistance | max. 60 V DC |
Output overvoltage protection | < 60 V DC |
Active current limitation | Approx. IBOOST= 22.5 A (for short-circuit) |
Control deviation | < 1 % (change in load, static 10 % ... 90 %) |
< 4 % (change in load, dynamic 10 % ... 90 %) | |
< 0.1 % (change in input voltage ±10 %) | |
Residual ripple | < 50 mVPP(with nominal values) |
Output power | 960 W |
Typical response time | < 1 s |
Maximum power dissipation in no-load condition | 24 W |
Power loss nominal load max. | 70 W |
Net weight | 2.5 kg |
---|---|
Efficiency | > 93 % (at 400 V AC and nominal values) |
Insulation voltage input/output | 4 kV AC (type test) |
2 kV AC (routine test) | |
Insulation voltage input / PE | 3.5 kV AC (type test) |
2 kV AC (routine test) | |
Insulation voltage output / PE | 500 V DC (routine test) |
Protection class | I |
Degree of protection | IP20 |
MTBF (IEC 61709, SN 29500) | > 890000 h (25 °C) |
> 509000 h (40 °C) | |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Assembly instructions | alignable: PN≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN<50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 10 |
Stripping length | 7 mm |
Screw thread | M3 |
Connection method | Screw connection |
---|---|
Conductor cross section solid min. | 0.5 mm² |
Conductor cross section solid max. | 16 mm² |
Conductor cross section flexible min. | 0.5 mm² |
Conductor cross section flexible max. | 16 mm² |
Conductor cross section AWG min. | 8 |
Conductor cross section AWG max. | 6 |
Stripping length | 10 mm |
Screw thread | M3 |
Conductor cross section solid min. | 0.2 mm² |
---|---|
Conductor cross section solid max. | 6 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 4 mm² |
Conductor cross section AWG min. | 18 |
Conductor cross section AWG max. | 10 |
Screw thread | M3 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Noise immunity | EN 61000-6-2:2005 |
Connection in acc. with standard | CSA |
Standards/regulations | EN 61000-4-2 |
Contact discharge | 4 kV (Test Level 2) |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 1 GHz |
Test field strength | 10 V/m (Test Level 3) |
Frequency range | 1.4 GHz ... 2 GHz |
Test field strength | 3 V/m (Test Level 2) |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-6 |
Frequency range | 0.15 MHz ... 80 MHz |
Voltage | 10 V (Test Level 3) |
Low Voltage Directive | Conformance with LV directive 2006/95/EC |
Standard - Safety of transformers | IEC 61558-2-17 |
Standard - Electrical safety | IEC 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard - Safe isolation | DIN VDE 0100-410 |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
Standard - Equipment safety | BG (design tested) |
Standard - Approval for medical use | IEC 60601-1, 2 x MOOP |
UL approvals | UL Listed UL 508 |
UL/C-UL Recognized UL 60950-1 (3-wire + PE, star net) | |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz ... 150 Hz, 2.3g, 90 min. | |
Information technology equipment - safety (CB scheme) | CB Scheme |
Rail applications | EN 50121-4 |
Overvoltage category (EN 62477-1) | III |
China RoHS | Environmentally Friendly Use Period = 25; |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2320827-QUINT-PS/3AC/48DC/20 | 132 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.