SACCBP-M12MS-5CON-M16/0,5-920 1534423 PHOENIX CONTACT Bus system flush-type plug, DeviceNet/CANopen, 5-pos.,.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SACCBP-M12MS-5CON-M16/0,5-920 1534423 PHOENIX CONTACT Bus system flush-type plug, DeviceNet/CANopen, 5-pos.,..

SACCBP-M12MS-5CON-M16/0,5-920

1534423

PHOENIX_CONTACT

Available

Ship on today

Bus system flush-type plug, DeviceNet/CANopen, 5-pos., M12, shielded, A-coded, rear/screw mounting with M16 thread, with 0.5 m bus cable, 2 x 0.2 mm², 2 x 0.32 mm²

More details


Core End Sleeves Cable Crimp

PLUSCON Field cabling - PHOENIX CONTACT

Data plug connectors – PLUSCON data. Cabling - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$31.35
8+$28.23
15+$27.60
22+$27.28
29+$27.07
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Length of cable0.5 m

Ambient conditions

Ambient temperature (operation)-25 °C ... 85 °C (Plug / socket)
-40 °C ... 85 °C (without mechanical actuation)
Degree of protectionIP67

General

NoteThe electrical and mechanical data specified assume that the connector pair is correctly locked and mounted. If the connector is unlocked and if there is a danger of contamination, the connector must be sealed using a protective cap > IP54. Influences arising from litz wires, cables or PCB assembly must also be taken into consideration.
Rated current at 40°C4 A
Rated voltage60 V
Rated surge voltage1.5 kV
Number of positions5
Insulation resistance≥ 100 MΩ
CodingA - standard
Standards/regulationsM12 connector IEC 61076-2-101
Status displayNo
Overvoltage categoryII
Pollution degree3
Test voltage2500 V
Insertion/withdrawal cycles> 100
Torque2 Nm ... 3 Nm (Installation-side)

Material

Flammability rating according to UL 94V0
Contact materialCuZn
Contact surface materialNi/Au
Contact carrier materialPA 66
Material, knurlsNickel-plated brass
Sealing materialFKM

Cable

Cable typeCAN Bus/DeviceNet
Cable type (abbreviation)920
UL AWM style21198 (80°C/300 V)
Cable structure2xAWG24/19+2xAWG22/19
Conductor cross section2x 0.25 mm² (Data cable)
2x 0.34 mm² (Power supply)
1x 0.34 mm² (Drain wire)
AWG signal line24
AWG power supply22
Conductor structure signal line19x 0.13 mm
Conductor structure, voltage supply19x 0.15 mm
Core diameter including insulation1.95 mm ±0.05 mm (Data cable)
1.4 mm ±0.05 mm (Power supply)
Wire colorsRed-black, blue-white
Twisted pairs2 cores to the pair
Type of pair shieldingPlastic-coated aluminum foil, aluminum side outside
Overall twist2 pairs around a drain wire in the center to the core
ShieldingTinned copper braided shield
Optical shield covering80 %
External sheath, colorviolet RAL 4001
External cable diameter D6.7 mm ±0,3 mm
Minimum bending radius, flexible installation10 x D
Number of bending cycles5000000
Bending radius70 mm
Traversing path4.5 m
Traversing rate3 m/s
Acceleration3 m/s²
Outer sheath, materialPUR
Material conductor insulationFoamed PE (Data cable)
PE (Power supply)
Conductor materialTin-plated Cu litz wires
Insulation resistance≥ 5 GΩ*km (Data cable)
≥ 5 GΩ*km (Power supply)
Conductor resistance≤ 90.9 Ω/km (Data cable)
≤ 57.4 Ω/km (Power supply)
Cable capacitynom. 40 pF/m (Data cable)
Wave impedance120 Ω ±10 % (with 1 MHz)
Wave attenuation≥ 0.0229 dB/m (with 1 MHz)
Nominal voltage, cable≤ 300 V (Peak value, not for high-power applications)
Test voltage Core/Core2000 V (50 Hz, 1 min.)
Test voltage Core/Shield2000 V (50 Hz, 1 min.)
Flame resistanceUL 1581, Sec. 1060 (FT-1)
IEC 60332-1
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
Halogen-freein accordance with DIN VDE 0472 part 815
According to IEC 60754-1
Other resistanceLow adhesion
Ambient temperature (operation)-40 °C ... 80 °C (cable, fixed installation)
-20 °C ... 80 °C (cable, flexible installation)
≤ 70 °C (cable, drag chain applications)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-1534423-SACCBP-M12MS-5CON-M16/0,5-920English154 KbytesPHOENIX CONTACT-1534423-SACCBP-M12MS-5CON-M16/0,5-920

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or