VAL-SEC-T2-3S-175-FM 2905354 VAL‐CP‐3S‐175 2859453 PHOENIX CONTACT Type 2 surge arrester View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VAL-SEC-T2-3S-175-FM 2905354 VAL‐CP‐3S‐175 2859453 PHOENIX CONTACT Type 2 surge arrester

VAL-SEC-T2-3S-175-FM

2905354

VAL‐CP‐3S‐175 2859453

PHOENIX_CONTACT

Type 2 surge arrester

More details


Trabtech (TT)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $339.34
Unit price: $339.34

Quantity Price
1+$339.34
2+$335.73
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2905354
Packing unit1 pc
Catalog pagePage 48 (C-4-2017)
GTIN4046356948029
Weight per Piece (excluding packing)222.220 g
Custom tariff number85363030
Country of originDE (Germany)

Dimensions

Height97.9 mm
Width49.2 mm
Depth74.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch2.7 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-40 °C ... 80 °C
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 500 Hz / 2.5 h / X, Y, Z)

General

IEC test classificationII
T2
EN typeT2
IEC power supply systemTN-S
TT
Mode of protectionL-N
L-PE
N-PE
Mounting typeDIN rail: 35 mm
Colorlight grey RAL 7035
traffic grey A RAL 7042
Housing materialPA 6.6-FR 20% GF
PBT-FR
Degree of pollution2
Flammability rating according to UL 94V-0
TypeDIN rail module, two-section, divisible
Number of positions4
Surge protection fault messageOptical, remote indicator contact

Protective circuit

Nominal voltage UN120/208 V AC (TN-S)
120/208 V AC (TT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous operating voltage UC(L-N)175 V AC
Maximum continuous operating voltage UC(L-PE)175 V AC
Maximum continuous voltage UC(N-PE)150 V AC
Rated load current IL40 A (Biconnect M4 fork-type cable lug 6​ mm²)
63 A (TWIN ferrule 2 x 10 mm²)
Residual current IPE≤ 1 µA
Nominal discharge current In(8/20) µs20 kA
Maximum discharge current Imax(8/20) µs40 kA
Follow current interrupt rating Ifi(N-PE)100 A (150 V AC)
Short-circuit current rating ISCCR25 kA (in case of 315 A gG backup fuse)
50 kA (in case of 200 A gG backup fuse)
Voltage protection level Up(L-N)≤ 0.85 kV
Voltage protection level Up(L-PE)≤ 1.3 kV
Voltage protection level Up(N-PE)≤ 0.95 kV
Residual voltage Ures(L-N)≤ 0.85 kV (at In)
≤ 0.75 kV (at 10 kA)
≤ 0.65 kV (at 5 kA)
≤ 0.63 kV (at 4 kA)
≤ 0.57 kV (at 2 kA)
Residual voltage Ures(N-PE)≤ 0.4 kV (at In)
≤ 0.4 kV (at 10 kA)
≤ 0.4 kV (at 5 kA)
≤ 0.4 kV (at 4 kA)
≤ 0.4 kV (at 2 kA)
TOV behavior at UT(L-N)240 V AC (5 s / withstand mode)
240 V AC (120 min / safe failure mode)
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Response time tA(L-N)≤ 25 ns
Response time tA(L-PE)≤ 100 ns
Response time tA(N-PE)≤ 100 ns
Max. backup fuse with V-type through wiring40 A (gG / Biconnect M4 fork-type cable lug, 6​ mm²)
63 A (gG / TWIN ferrule 2x 10mm²)
Max. backup fuse with branch wiring315 A (gG)

Indicator/remote signaling

Switching functionPDT contact
Operating voltage5 V AC ... 250 V AC
125 V DC (200 mA DC)
Operating current5 mA AC ... 1 A AC
1 A DC (30 V DC)
Connection methodPlug-in/screw connection via COMBICON
Screw threadM2
Tightening torque0.25 Nm
Stripping length7 mm
Conductor cross section flexible0.14 mm² ... 1.5 mm²
Conductor cross section solid0.14 mm² ... 1.5 mm²
Conductor cross section AWG28 ... 16

Connection data

Connection methodScrew connection
Screw threadM5
Tightening torque4.5 Nm
Stripping length16 mm
Conductor cross section flexible2.5 mm² ... 16 mm²
Conductor cross section solid2.5 mm² ... 25 mm²
Conductor cross section AWG12 ... 4
Connection methodFork-type cable lug
Conductor cross section flexible1.5 mm² ... 6 mm²

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (L-L)350 V AC
Maximum continuous operating voltage MCOV (L-N)175 V AC
Maximum continuous operating voltage MCOV (L-G)175 V AC
Maximum continuous operating voltage MCOV (N-G)150 V AC
Nom. voltage120/208 V AC
Mode of protectionL-L
L-N
L-G
N-G
Power distribution systemWye
Nominal frequency50/60 Hz
Measured limiting voltage MLV (L-L)2010 V
Measured limiting voltage MLV (L-N)1510 V
Measured limiting voltage MLV (L-G)1630 V
Measured limiting voltage MLV (N-G)560 V
Nominal discharge current In(L-L)20 kA
Nominal discharge current In(L-N)20 kA
Nominal discharge current In(L-G)20 kA
Nominal discharge current In(N-G)20 kA

UL indicator/remote signaling

Operating voltage125 V AC
Operating current1 A AC
Tightening torque2 lbf-in. ... 4 lbf-in.
Conductor cross section AWG30 ... 14

UL connection data

Conductor cross section AWG14 ... 2 (solid)
14 ... 4 (flexible)
Tightening torque40 lbf-in. ... 50 lbf-in.

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Environmental Product Compliance

REACh SVHCLead 7439-92-1

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.