10
PLC-INTERFACE for high continuous currents, consisting of PLC-BPT.../21 HC basic terminal block with push-in connection and plug-in miniature relay, for mounting on DIN rail NS 35/7,5, limiting continuous current up to 10 A, 1 PDT, input voltage 24 V AC/DC
INTERFACE Components (IF)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Width | 14 mm |
---|---|
Height | 80 mm |
Depth | 94 mm |
Ambient temperature (operation) | -40 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Nominal input voltage UN | 24 V AC/DC |
---|---|
Typical input current at UN | 17.5 mA |
Typical response time | 8 ms |
Typical release time | 10 ms |
Protective circuit | Bridge rectifier Bridge rectifier |
Operating voltage display | Yellow LED |
Power dissipation for nominal condition | 0.42 W |
Contact type | 1 PDT |
---|---|
Contact material | AgNi |
Maximum switching voltage | 250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
Minimum switching voltage | 12 V DC (at 10 mA) |
Min. switching current | 10 mA (at 12 V) |
Maximum inrush current | 30 A (300 ms) |
Limiting continuous current | 10 A |
6 A (value applies to connections 12. If connections 12 are bridged, the normal value applies.) | |
Interrupting rating (ohmic load) max. | 240 W (at 24 V DC) |
58 W (at 48 V DC) | |
48 W (at 60 V DC) | |
50 W (at 110 V DC) | |
80 W (at 220 V DC) | |
2500 VA (for 250 V AC) | |
Interrupting rating (ohmic load) max. bridged | 144 W (for 24 V DC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.) |
1500 VA (for 250 V AC. Value applies to connections 12. If connections 12 are bridged, the normal value applies.) | |
Switching capacity in acc. with DIN VDE 0660/IEC 60947 | 2 A (at 24 V, DC13) |
0.2 A (at 110 V, DC13) | |
0.2 A (at 250 V, DC13) | |
6 A (at 24 V, AC15) | |
6 A (at 120 V, AC15) | |
6 A (at 250 V, AC15) |
Operating mode | 100% operating factor |
---|---|
Degree of protection | RT II (Relay) |
Mechanical service life | 3 x 107cycles |
Flammability rating according to UL 94 | V0 |
Designation | Standards/regulations |
Standards/regulations | IEC 60664 |
EN 50178 | |
IEC 62103 | |
Rated surge voltage/insulation | 6 kV / Safe isolation, increased insulation |
Pollution degree | 2 |
Overvoltage category | III |
Mounting position | any |
Assembly instructions | In rows with zero spacing |
Connection name | Coil side |
---|---|
Connection method | Push-in connection |
Stripping length | 8 mm |
Conductor cross section solid | 0.14 mm² ... 2.5 mm² |
Conductor cross section flexible | 0.14 mm² ... 2.5 mm² |
Conductor cross section AWG | 26 ... 14 |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2900293-PLC-RPT- 24UC/21HC | 162 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.