PLC-INTERFACE, consisting of PLC-BPT.../21-21 basic terminal block with push-in connection and plug-in miniature relay with multi-layer gold contact, for mounting on DIN rail NS 35/7,5, 2 PDTs, input voltage 120 V AC/DC

More details


Converters

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Solid state relays and power electronics. Relay - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+$12.14
20+$11.83
30+$11.68
40+$11.58
50+$11.55
*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width14 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN120 V AC (110 V DC)
110 V DC
Typical input current at UN4.2 mA (at 110 V DC)
4.5 mA (for 120 V AC)
Typical response time7 ms
Typical release time10 ms
Protective circuitBridge rectifier Bridge rectifier
Operating voltage displayYellow LED
Power dissipation for nominal condition0.54 W

Contact side

Contact type2 PDT
Contact materialAgNi, hard gold-plated
Maximum switching voltage30 V AC
36 V DC
Minimum switching voltage100 mV (at 10 mA)
Min. switching current1 mA (at 24 V)
Maximum inrush current50 mA
Limiting continuous current50 mA
Interrupting rating (ohmic load) max.1.2 W (at 24 V DC)
Notethe following values are applicable if a gold layer is destroyed
Maximum switching voltage250 V AC/DC
Minimum switching voltage5 V AC/DC
Limiting continuous current6 A
Maximum inrush current15 A (300 ms)
Min. switching current10 mA
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
85 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
60 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity in acc. with DIN VDE 0660/IEC 609472 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
2 A (at 24 V, AC15)
2 A (at 120 V, AC15)
2 A (at 250 V, AC15)

General

Operating mode100% operating factor
Degree of protectionRT III (Relay)
Mechanical service life3 x 107 cycles
Flammability rating according to UL 94V0
DesignationStandards/regulations
Standards/regulationsIEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulation6 kV/Basic isolation
Pollution degree2
Overvoltage categoryIII
Mounting positionany
Assembly instructionsIn rows with zero spacing

Connection data input side

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²