PLC-INTERFACE, integrated solid-state relay, with screw connection, for mounting on NS 35/7,5 DIN rails, input: 120 V AC, output: 12 - 300 V DC/1 A

More details


Converters

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Cabling and interface cabling systems. Cabling - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+$46.20
20+$45.47
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width6.2 mm
Height80 mm
Depth86 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Input data

Nominal input voltage UN120 V AC
Input voltage range in reference to UN0.8 ... 1.1
Switching threshold "0" signal in reference to UN≤ 0.4
Switching threshold "1" signal in reference to UN≥ 0.8
Typical input current at UN5.6 mA
Typical response time19 ms
Typical turn-off time6 ms
Operating voltage displayYellow LED
Type of protectionBridge rectifier
Protective circuit/componentBridge rectifier
Transmission frequency10 Hz

Output data

DesignationOutput data
Output voltage range12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Limiting continuous current1 A (see derating curve)
Voltage drop at max. limiting continuous current< 500 mV
Type of protectionProtection against polarity reversal
Surge protection
Protective circuit/componentPolarity protection diode
Varistor

Connection data, input side

Connection nameInput side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

General

Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Flammability rating according to UL 94V0
DesignationStandards/regulations
Standards/regulationsIEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulation4 kV / basic insulation
Rated insulation voltage300 V
Pollution degree2
Overvoltage categoryIII

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2980717-PLC-OSC-120AC/300DC/ 1English127 KbytesPHOENIX CONTACT-2980717-PLC-OSC-120AC/300DC/ 1

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or