PLC-INTERFACE for output functions, consisting of PLC-BSC…/A - PHOENIX CONTACT - PLC-RSC- 24DC/ 1/ACT - 2966210 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-INTERFACE for output functions, consisting of PLC-BSC…/A - PHOENIX CONTACT - PLC-RSC- 24DC/ 1/ACT - 2966210






Ship on today

PLC-INTERFACE for output functions, consisting of PLC-BSC…/ACT basic terminal block with screw connection and plug-in miniature relay with power contact, for mounting on DIN rail NS 35/7,5, 1 N/O contact, input voltage 24 V DC

More details


INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Cabling and interface cabling systems. Cabling - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

Price: $10.43
*This price is per unit and is the net value (not including taxes if applicable).
Up to 35% discount for registered clients.

Request a quote
How it Works

How does the quotation request work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with our price proposals
4 You can directly process the order for the quotation

There are several options for payment
- Credit card
- Wire Transfer
- PayPal

More info


Width6.2 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 60 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V DC
Typical input current at UN9 mA
Typical response time5 ms
Typical release time8 ms
Protective circuitProtection against polarity reversal Polarity protection diode
Free-wheeling diode Damping diode
Operating voltage displayYellow LED
Power dissipation for nominal condition0.22 W

Contact side

Contact type1 N/O contact
Contact materialAgSnO
Maximum switching voltage250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
Minimum switching voltage5 V (at 100 mA)
Min. switching current10 mA (at 12 V)
Maximum inrush currenton request
Limiting continuous current6 A
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity in acc. with DIN VDE 0660/IEC 609472 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)


Test voltage relay winding/relay contact4 kV AC (50 Hz, 1 min.)
Operating mode100% operating factor
Mechanical service life2 x 107 cycles
Flammability rating according to UL 94V0
Standards/regulationsIEC 60664
EN 50178
IEC 62103
Pollution degree3
Overvoltage categoryIII
Mounting positionany
Assembly instructionsIn rows with zero spacing

Connection data input side

Connection nameCoil side
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

PDF of PLC-INTERFACE for output functions, consisting of PLC-BSC…/A - PHOENIX CONTACT - PLC-RSC- 24DC/ 1/ACT - 2966210

PHOENIX CONTACT-2966210-PLC-RSC- 24DC/ 1/ACTEnglish97 KbytesPHOENIX CONTACT-2966210-PLC-RSC- 24DC/ 1/ACT