Safety-related digital output module, IP20 protection, for the SafetyBridge system. The module has four safe digital outputs with two-channel occupancy or 8 safe digital outputs with single-channel occupancy

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The safety module is an output module from the Inline product range and is used in a SafetyBridge system. The safety module can be used as a part of an Inline station at any point within an INTERBUS, PROFINET or PROFIBUS system. The transmission speed of the safety module can be set to 500 kbaud or 2 Mbaud using a switch. Only one transmission speed must be used uniformly within a station. The module has four safe digital outputs with two-channel occupancy or eight safe digital outputs with single-channel occupancy. In the SafetyBridge system, you can achieve the following safety integrity by using this safety module depending on the installation and parameterization:

– up to category 4 according to EN 954-1 standard,

– up to SIL 3 according to EN 61508 standard,

– up to SIL CL 3 according to EN 62061 standard,

– up to PL e according to EN ISO 13849-1 standard.

Dimensions

Width48.8 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsHousing dimensions

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Permissible humidity (storage/transport)10 % ... 85 % (Take suitable measures against increased air humidity within the permitted temperature range.)
Air pressure (operation)80 hPa ... 108 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)66 hPa ... 108 kPa (up to 3500 m above mean sea level)
Degree of protectionIP20

Interfaces

Fieldbus systemINTERBUS
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s / 2 MBit/s

Digital outputs

Output nameDigital outputs
Connection methodSpring-cage connection
2, 3, 4-wire
Number of outputs4 (with two-channel assignment)
8
Protective circuitOverload protection, short-circuit protection of outputs
Output voltage24 V DC (US - 1 V)
Nominal output voltage24 V DC
Output currentmax. 6 A (Total current of all outputs, -25 °C ... 50 °C)
max. 4 A (Total current of all outputs, >50 °C ... 55 °C)
Maximum output current per channel2 A
Maximum output current per group3 A
Nominal load, inductivesee safety data
Nominal load, lampsee safety data
Nominal load, ohmicsee safety data

Power supply for module electronics

Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC
Communications power UL7.5 V (via voltage jumper)
Current consumptionmax. 230 mA (from the local bus)

General

Net weight246.5 g
Note on weight specificationswith connectors
Mounting typeDIN rail
Category according to EN 13849-14
Diagnostics messagesShort-circuit / overload of the digital outputs Error message in diagnostics code (bus) and display by means of the LED on the motor

Inline potentials

Communications power UL7.5 V DC (see safety data)
Current consumption from ULmax. 230 mA (see safety data)
Main circuit supply UM24 V DC (see safety data)
Supply voltage range UM19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumption from UMtyp. 30 mA (all outputs set including actuator current)
max. 6.03 A
Segment supply voltage US24 V (see safety data)

SafetyBridge properties

Connection to I/O modulesmax. 3 (safe digital input modules)
Logic memory6 kByte

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2916024-IB IL 24 LPSDO 8-PACEnglish110 KbytesPHOENIX CONTACT-2916024-IB IL 24 LPSDO 8-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or