NAMUR isolation amplifier,2-channel for operating proximity sensors and switches. The signals are transferred to the control level using relay outputs (N/O contact). Line fault detection (LFD), galvanic 3-way isolation, SIL 2.

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$141.26
2+$137.41
3+$135.50
4+$134.28
6+$132.81
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width12.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 EN 61326 When being exposed to interference, there may be minimal deviations.
Degree of protectionIP20

Input data

Non-load voltage~ 8 V DC
Switching points (attenuated)< 1.2 mA (blocking)
Switching points (unattenuated)> 2.1 mA (conductive)

Output data

Switching outputRelay output
Contact type1 N/O contact per channel
Contact materialAgSnO2, hard gold-plated
Maximum switching voltage250 V AC (2 A)
120 V DC (0.2 A)
30 V DC (2 A)
Maximum switching capacity500 VA
Mechanical service life107 cycles

Power supply

Nominal supply voltage24 V DC -20 % ... +25 %
Supply voltage range19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
Max. current consumption35 mA (24 V DC)
Power consumption< 1 W

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

No. of channels2
Status displayGreen LED (supply voltage)
LED yellow (switching state)
Red LED (line errors)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryIII
Emitted interferenceEN 61000-6-4
Housing materialPA 66-FR
Colorgreen
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/supply, DIN rail connector
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
DesignationOutput 1/output 2/input, power supply, T connector
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category III; pollution degree 2, safe isolation as per EN 61010-1))
DesignationOutput 1/output 2/input/power supply, DIN rail connector
Electrical isolation2.5 kV (50 Hz, 1 min., test voltage)
ConformanceCE-compliant, additionally EN 61326-1
ATEXEx II 3 G Ex nA nC IIC T4 Gc X
UL, USA / CanadaUL 508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
GLC, EMC1

Safety characteristic data

Integrity requirementIEC 61508 - Low demand
DesignationNon-inverted operation
Equipment typeType A
Safety Integrity Level (SIL)Up to 2
Safe Failure Fraction (SFF)78 %
λSU2.49 x 10-7 (249 FIT)
λSD6 x 10-9 (6 FIT)
λDU6.4 x 10-8 (64 FIT)
λDD7 x 10-9 (7 FIT)
Probability of a hazardous failure on demand (PFDAVG)3.09 x 10-4 (1 year)
6.17 x 10-4 (2 years)
1.54 x 10-3 (5 years)
Diagnostic coverage (DC)DCS = 2.4%, DCD = 9%
Integrity requirementIEC 61508 - Low demand
DesignationInverted operation
Equipment typeType A
Safety Integrity Level (SIL)Up to 2
Safe Failure Fraction (SFF)78 %
λSU2.48 x 10-7 (248 FIT)
λSD1 x 10-9 (1 FIT)
λDU6.2 x 10-8 (62 FIT)
λDD6 x 10-9 (6 FIT)
Probability of a hazardous failure on demand (PFDAVG)3.01 x 10-4 (1 year)
6.02 x 10-4 (2 years)
1.5 x 10-3 (5 years)
Diagnostic coverage (DC)DCS = 0.4%, DCD = 8%

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Evaluation criterionA
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Evaluation criterionA
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Evaluation criterionA

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2865049-MACX MCR-SL-2NAM-ROEnglish142 KbytesPHOENIX CONTACT-2865049-MACX MCR-SL-2NAM-RO

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or