PSR-PIP-24DC/MXF1/4X1/2X2/B 2903253 PHOENIX CONTACT Safety relays View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSR-PIP-24DC/MXF1/4X1/2X2/B 2903253 PHOENIX CONTACT Safety relays

PSR-PIP-24DC/MXF1/4X1/2X2/B

2903253

PHOENIX_CONTACT

Safety relays

More details


Safety

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2903253
Packing unit1 pc
Catalog pagePage 267 (C-6-2017)
GTIN4046356730181
Weight per Piece (excluding packing)204.880 g
Custom tariff number85371098
Country of originDE (Germany)

Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width22.5 mm
Height106.4 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 45 °C (see derating curve)
Ambient temperature (storage/transport)-25 °C ... 85 °C
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Maximum altitude≤ 2000 m (Above sea level)

Input data

Rated control circuit supply voltage US
Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.85 ... 1.1
Typical input current at UN125 mA (with actuated relays)
55 mA (Two-channel 24 V/0 V + max. 200 mA control (message outputs 32/62) with non-actuated relays)
Current consumptiontyp. 5 mA (Imax/Ixinputs)
20 mA (in electric torque)
Voltage at input/start and feedback circuit24 V -15 %; +10 % (first channel: 24 V; second channel: 0 V)
Typical response time175 ms (monitored/manual start)
250 ms (automatic start)
Typ. starting time with Us250 ms (when controlled via A1)
Typical release time25 ms (when controlled via S11/I1,I3,I5 and S21/I2,I4,I6)
20 ms (when controlled via A1)
Concurrence input 1/2
Recovery time1 s (Availability time after activation of sensor circuit: 100ms)
Operating voltage display1 x green LED
Status display5 green LEDs
Protective circuitSurge protection Suppressor diode
Maximum switching frequency0.5 Hz
Max. permissible overall conductor resistance100 Ω
Filter timemax. 1.5 ms (Test pulse duration; for all equivalent inputs)
min. 7.5 ms (Test pulse rate; for all equivalent inputs)

Output data

Contact type4 enabling current paths
2 semiconductor alarm outputs
Contact materialAgCuNi, +0.2 -0.4 µm Au
Maximum switching voltage250 V AC/DC
Minimum switching voltage10 V AC/DC
Limiting continuous current6 A (N/O contact)
max. 100 mA (Alarm output (24 V DC))
Maximum inrush current6 A
Inrush current, minimum10 mA
Sq. Total current72 A2(ITH2= I12+ I22+ I32+ I42)
Interrupting rating (ohmic load) max.1500 VA (250 V AC, τ = 0 ms)
66 W (220 V DC, τ = 0 ms)
66 W (110 V DC, τ = 0 ms)
100 W (48 V DC, τ = 0 ms)
144 W (24 V DC, τ = 0 ms)
Maximum interrupting rating (inductive load)48 W (24 V DC, τ = 40 ms)
43 W (48 V DC, τ = 40 ms)
Switching capacity min.0.1 W
Mechanical service life10x 106cycles
Switching capacity (360/h cycles)5 A (0,1 Hz; DC13; 24 V)
Output fuse6 A gL/gG NEOZED (N/O contact)
4 A gL/gG NEOZED (for low-demand applications)

General

Relay typeElectromechanical relay with forcibly guided contacts in accordance with EN 50205
Nominal operating mode100% operating factor
Net weight204.88 g
Mounting positionvertical or horizontal
Mounting typeDIN rail mounting
Assembly instructionsSee derating curve
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Housing coloryellow

Connection data

Connection methodPush-in connection
pluggableno
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Stripping length10 mm

Safety-related characteristic data

Stop category0
Safety Integrity Level (SIL)3
3
DesignationEN ISO 13849
Performance level (PL)e (5 A DC13; 3 A AC15; 8760 cycles/year)
Category4
Safety Integrity Level Claim Limit (SIL CL)3
DesignationEN 50156
Safety Integrity Level (SIL)3

Standards and Regulations

DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsDIN EN 50178/VDE 0160
Rated insulation voltage250 V AC
Rated surge voltage/insulation4 kV/basic isolation (safe isolation, reinforced insulation and 6 kV between input circuit, enabling current paths and safety circuit 1 (13/14, 23/24) and safety circuit 2 (43/44, 53/54).)
Degree of pollution2
Overvoltage categoryIII

Environmental Product Compliance

REACh SVHCLead 7439-92-1
China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.