Electromechanical reversing load motor starter for INTERBUS; fiber optic technology with 500 kbaud, inputs (24 V DC), integrated motor protection relay (220 V AC to 480 V AC; 8 A, maximum), sensor connection via 5-pos. M12 female connectors, rugged metal housing, IP67 protection

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width185.1 mm
Height193 mm
Depth138 mm

Ambient conditions

Ambient temperature (operation)0 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 70 °C
Permissible humidity (operation)100 %
Permissible humidity (storage/transport)95 % (non-condensing)
Air pressure (operation)860 hPa ... 1080 hPa (up to 1500 m above mean sea level)
Air pressure (storage/transport)660 hPa ... 1080 hPa (up to 3500 m above mean sea level)
Degree of protectionIP65/IP67

Interfaces

Fieldbus systemINTERBUS
DesignationINTERBUS
Connection methodFiber optics
Transmission speed500 kBit/s

Power supply for module electronics

Supply voltage24 V DC
Supply voltage range18.5 V DC ... 32 V DC (including ripple)
Ripple3.6 Vpp
Current consumptiontyp. 90 mA (plus power supply for sensors)

Mains connection

DesignationMains connection
Connection methodPOWER-COMBICON with silver contacts
Designation connection pointTerminal strip; X11 and X12
Number of positions4
Permissible conductor cross section2.5 mm² ... 4 mm²
Operating voltage230 V AC ... 480 V AC ±10 % (conductor voltage)
Max. current carrying capacity20 A

Motor starter, output

Connection methodPOWER-COMBICON
Number1
Designation connection pointX10
Number of positions8
Pg screw connectionPg16
Operating voltage230 V AC ... 480 V AC
Frequency range50 Hz ... 60 kHz
Nominal current range0.2 A ... 8 A (parameterizable, observe derating)
Utilization categoryOn the basis of AC 3
Switching rate5 cycles per minute, maximum
Motor startup time1 s

Motor monitoring

ParameterizationVia INTERBUS
Overspeed tripping≥ 40 A (after 1 second at Inom > 3.6 A)

Motor starter, brake

Continuous load currentmax. 1 A
Type of contactMechanical relay contact
Connection methodPOWER-COMBICON terminal strips
Connection voltage12 V AC/DC ... 480 V AC/DC

Digital inputs

Input nameDigital inputs
Number of inputs6
Connection methodM12 connector
3, 4-wire
Number of positions5
Input voltage24 V DC (DIN EN 61131-2)
Input voltage range "0" signal0 V ... 5 V
Input voltage range "1" signal11 V ... 30 V
Typical input current per channel5 mA (for US1 = 24 V)
Filter time3 ms
Power supply for sensorsUINI = US1 minus 1 V 50 mA Protected against inductive reverse voltages, electronically protected against short-circuiting

Digital outputs

Number of outputs1
Connection methodM12 connector
Number of positions5
Output current0.5 A
Minimum output voltage with nominal currentUS1 minus 2 V
Type of protectionElectronic short-circuit/overload protection

General

Net weight3800 g
Mounting typeWall mounting
Diagnostics messagesMains failure, phase failure, blown fuse Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Sensor supply failure Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Failure of the actuator supply Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Motor overcurrent Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Output stage cannot be controlled Error message in diagnostic code (bus) and display by means of the E LED on the motor starter
Module error during self test Message to the master
Mounting typeOn mounting plate

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2737384-IBS RL 480 MLR R DIO6/1-LKEnglish106 KbytesPHOENIX CONTACT-2737384-IBS RL 480 MLR R DIO6/1-LK

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or