IBS IP 400 ME-MLR 2-8A DI4F 2732965 PHOENIX CONTACT Electromechanical motor starter, electronic module witho.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IBS IP 400 ME-MLR 2-8A DI4F 2732965 PHOENIX CONTACT Electromechanical motor starter, electronic module witho..

IBS IP 400 ME-MLR 2-8A DI4F

2732965

PHOENIX_CONTACT

Available

Ship on today

Electromechanical motor starter, electronic module without lower part of housing, 2-channel direct starter

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

>>! Spare product (module electronics) for the motor starter: 28 36 010 IBS IP 400 MLR 2-8A DI 4/4-F without housing lower part 27 32 868 IBS IP 400 MBH-F - see motor starter accessories) !<<

The motor starter modules allow three-phase standard motors to be switched via INTERBUS and are available with two housing variants.

The standard housing in IP54 protection is especially suited for direct use in machines and systems in conveyor technology, whereas the high-grade steel variant in IP67 protection is designed for installation in food industry systems.

Since they are available in different versions, INTERBUS motor starters cover the most important applications.

The 1- and 2-channel motor starters allow direct drives to be controlled and there are reversing load versions for applications involving different drive directions.

If different speeds are required, the variable frequency drives provide the right control.

The features include:

- Easy installation and pluggable connections

- Removable module electronics

- Power networking:

Motor starter 400 V AC / 20 A

Variable frequency drive 500 V AC / 20 A

- Comprehensive status and diagnostics displays on the module

- Startup without bus possible with manual operate function (with VFD also with RS-232)

- Initiator inputs for the connection of sensors and

- High-grade steel housing, which is extremely resistant to cleaning agents and

- Sheet steel housing, ideal for use in the plant, with pluggable cable feed-throughs for ready-assembled cable.

Dimensions

Width384 mm
Height182 mm
Depth100 mm
Note on dimensionsModule electronics without lower part
Drill hole spacing360 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 55 °C (non-condensing)
Ambient temperature (storage/transport)-25 °C ... 75 °C
Permissible humidity (operation)4 % ... 100 % (non-condensing)
Permissible humidity (storage/transport)75 % (slight temporary condensation may sometimes appear on the housing)
Air pressure (operation)86 kPa ... 106 kPa (up to 2000 m above mean sea level)
Air pressure (storage/transport)86 kPa ... 106 kPa (up to 2000 m above mean sea level)
Degree of protectionIP67

Interfaces

Fieldbus systemINTERBUS
DesignationINTERBUS
Connection methodMINI COMBICON
Designation connection pointX30 (IN) and X31 (OUT)
Number of positions10
Permissible conductor cross sectionmax. 1.5 mm²

Power supply for module electronics

Connection methodPOWER-COMBICON
DesignationTerminal strip X13 and X15
Number of positions2
Pg screw connectionPg11
Supply voltage24 V DC (US1 / US2)
Supply voltage range20 V DC ... 30 V DC (including ripple)
RipplePermissible ripple 3.6 Vpp within the permissible voltage range
Supply currenttyp. 0.11 A (at US1 = 24 V; plus current of digital inputs/outputs)
Max. current carrying capacity16 A
DeratingAbove 30°C: 0.1 A/ K (at 4 mm²), above 30°C: 0.3 A/ K (at 1.5 mm²)

Mains connection

DesignationMains connection
Connection methodPOWER-COMBICON with silver contacts
Designation connection pointTerminal strip; X11 and X12
Number of positions4
Permissible conductor cross section2.5 mm² ... 4 mm²
Pg screw connectionPg16
Operating voltage360 V AC ... 440 V AC (line voltage 50/60 Hz)
Max. current carrying capacity20 A

Motor starter, output

Connection methodPOWER-COMBICON
Number2
Output nameMotor outputs (3 phases), short-circuit-proof with external line protection fuse 10 A
Designation connection pointTerminal strip; X10
Number of positions8
Permissible conductor cross section1 mm² ... 2.5 mm²
Pg screw connectionPg11
Operating voltage360 V AC ... 440 V AC (line voltage 50/60 Hz)
Frequency range50 Hz ... 60 Hz (mains frequency)
Nominal current range0.2 A ... 8 A
Utilization categoryOn the basis of AC 3
Switching rateMax. 5 cycles per minute
Motor startup time1 s

Motor monitoring

ParameterizationVia INTERBUS
Parameterization range0.2 A ... 8 A
Overspeed tripping≥ 15 A (after 1 second at Inom ≤ 3.6 A)

Motor starter, brake

Number of outputs1
DesignationBrake relays
Continuous load currentmax. 1 A
Type of contactMechanical relay contact
Connection methodWith POWER-COMBICON terminal strip of the motor connection (X10)
Connection voltage12 V DC ... 620 V DC

Thermistor input

Number of inputs1
DesignationThermistor input 1 (21, 22)
Sensor types that can be used (TC)Kaltleiter nach DIN 44081:1980
Connection methodPOWER-COMBICON terminal strips X10
2-wire
Operating range100 Ω ... 2.5 kΩ (total resistance)
Shutdown_range> 4000 Ω (excess temperature)
Maximum thermistor current1 mA
Working voltage2.5 V
Filter time100 ms
PotentialSafe isolation to 24 V supply voltage US1

Operator panel

Input nameInput for the handheld operating panel
Number of inputs3
Connection methodMINI COMBICON
Sockets X33 and X34
Number of positions10
Typical input current per channelapprox. 5 mA (for US1 = 24 V)
Filter time3 ms
PotentialPotential of supply voltage US1

Digital inputs

Input nameDigital inputs
Number of inputs4
Connection methodMINI COMBICON
3, 4-wire
Number of positions10
Input voltage24 V DC (US1)
Input voltage range "0" signal-30 V ... 5 V (binary "0")
Input voltage range "1" signal13 V ... 30 V (binary "1")
Typical input current per channelapprox. 5 mA (for US1 = 24 V)
Filter time3 ms
Power supply for sensorsUINI = US1 minus 2 V DC 50 mA Against inductive reverse voltages, polarity reversal and short-circuits

Digital outputs

Output nameDigital outputs
Number of outputs2
Connection methodMINI COMBICON
2-wire
Number of positions10
Output currentmax. 500 mA (per channel)
Minimum output voltage with nominal currentUS1 minus 2 V
Type of protectionElectronic short-circuit/overload protection, damping diode

General

Net weight2307.7 g
Note on weight specificationsModule electronics without lower part
Mounting typeWall mounting
NoteNotes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Notes on operation Permitted network type TN network, TT network, IT network available on request
Diagnostics messagesMains failure, phase failure Error message in the diagnostic code (bus) and display via the LED ERR on the module
Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited Error message in the diagnostic code (bus) and display via the LED ERR on the module
Sensor supply failure Error message in the diagnostic code (bus) and display via the LED ERR on the module
Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Module error during self test Message to the master

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2732965-IBS IP 400 ME-MLR 2-8A DI4FEnglish166 KbytesPHOENIX CONTACT-2732965-IBS IP 400 ME-MLR 2-8A DI4F

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or