Module electronics, one-channel electronic reverse starter, PROFIBUS-DP connection, electronic motor monitoring can be used to switch on/off a three-phase asynchronous motor

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width355 mm
Height180 mm
Depth100 mm
Note on dimensionsModule electronics without lower part
Drill hole spacing386 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 55 °C (non-condensing)
Ambient temperature (storage/transport)-25 °C ... 75 °C
Permissible humidity (operation)4 % ... 100 % (non-condensing)
Permissible humidity (storage/transport)75 % (slight temporary condensation may sometimes appear on the housing)
Air pressure (operation)86 kPa ... 106 kPa (up to 2000 m above mean sea level)
Air pressure (storage/transport)86 kPa ... 106 kPa (up to 2000 m above mean sea level)
Degree of protectionIP54

Interfaces

Fieldbus systemPROFIBUS DP
DesignationPROFIBUS interface
Connection methodM12 connector, B-coded
Designation connection pointM12 connector; X30 (IN) and X31 (OUT)
Number of positions5
Permissible conductor cross section0.25 mm² ... 0.75 mm² (stranded)

Power supply for module electronics

Connection methodPOWER-COMBICON
DesignationTerminal strip X13 and X15
Number of positions2
Pg screw connectionPg16R
Supply voltage24 V DC (US1)
Supply voltage range20 V DC ... 30 V DC (including ripple)
RipplePermissible ripple 3.6 Vpp within the permissible voltage range
Supply currenttyp. 0.17 A (at US1 = 24 V; plus current of digital inputs/outputs)
Max. current carrying capacity16 A
DeratingFrom 30°C 0.1A/K

Mains connection

DesignationMains connection
Connection methodPOWER-COMBICON with silver contacts
Designation connection pointTerminal strip; X11 and X12
Number of positions4
Permissible conductor cross section2.5 mm² ... 4 mm²
Pg screw connectionPg16
Operating voltage360 V AC ... 440 V AC (conductor voltage)
Max. current carrying capacity20 A

Motor starter, output

Connection methodPOWER-COMBICON
Number1
Output nameMotor outputs (3 phases), not short-circuit proof
Designation connection pointTerminal strip; X10
Number of positions8
Permissible conductor cross section1 mm² ... 1.5 mm²
Pg screw connectionPg16
Operating voltage360 V AC ... 440 V AC (line voltage 50/60 Hz)
Frequency range50 Hz ... 60 Hz (mains frequency)
Nominal current range0.2 A ... 3.6 A
Utilization categoryOn the basis of AC 53a
Switching rateMax. 24 per minute (observe derating)
Motor startup time0.5 s
Min. switch-on time1 s
Min. switch-off time1 s
Fuse typeSafety fuse 10 AT

Motor monitoring

ParameterizationVia PROFIBUS
Parameterization range0.2 A ... 3.6 A
Overspeed tripping≥ 15 A (after 1 second)

Motor starter, brake

Number of outputs1
DesignationBrake relays
Continuous load currentmax. 0.3 A
Type of contactPolarized semi-conductor contact
Connection methodWith POWER-COMBICON terminal strip of the motor connection (X10)
Connection voltage12 V DC ... 620 V DC
Residual voltagemax. 2.5 V DC

Thermistor input

Number of inputs1
DesignationThermistor input 1 (11, 12)
Sensor types that can be used (TC)Kaltleiter nach DIN 44081:1980
Connection methodPOWER-COMBICON terminal strips X10
2-wire
Operating range100 Ω ... 2.5 kΩ (total resistance)
Shutdown_range> 4000 Ω (excess temperature)
≤ 10 Ω (short-circuit of the thermistor cable)
Maximum thermistor current1 mA
Working voltage2.5 V
Filter time100 ms
PotentialSafe isolation to 24 V supply voltage US1

Operator panel

Input nameInput for the handheld operating panel
Number of inputs3
Connection methodM12 connector, (A-coded)
Sockets X32
Number of positions5
Typical input current per channelapprox. 5 mA (for US1 = 24 V)
Filter time3 ms
PotentialPotential of supply voltage US1

Digital inputs

Input nameDigital inputs
Number of inputs4
Connection methodM12 connector, (A-coded)
3, 4-wire
Number of positions5
Input voltage24 V DC (US1)
Input voltage range "0" signal-30 V ... 5 V (binary "0")
Input voltage range "1" signal13 V ... 30 V (binary "1")
Typical input current per channelapprox. 5 mA (for US1 = 24 V)
Filter time3 ms
Power supply for sensorsUINI = US1 minus 2 V DC 50 mA Against inductive reverse voltages, polarity reversal and short-circuits

Digital outputs

Output nameDigital outputs
Number of outputs2
Connection methodM12 connector, (A-coded)
2-wire
Number of positions5
Output currentmax. 500 mA (per channel)
Minimum output voltage with nominal currentUS1 minus 2 V
Type of protectionElectronic short-circuit/overload protection, damping diode

General

Net weight3268.7 g
Note on weight specificationsModule electronics without lower part
Mounting typeWall mounting
NoteNotes on operation Line protection for the network supply line, max. 20 A. Observe derating of the POWER-COMBICON connector
Notes on operation Permitted network type TN network, TT network, IT network available on request
Diagnostics messagesMains failure, phase failure Error message in the diagnostic code (bus) and display via the LED ERR on the module
Motor connector not plugged in, motor temperature exceeded, thermistor line short-circuited Error message in the diagnostic code (bus) and display via the LED ERR on the module
Sensor supply failure Error message in the diagnostic code (bus) and display via the LED ERR on the module
Overcurrent Error message in the diagnostic code (bus) and display via the LED ERR on the module
Output stage cannot be controlled Error message in the diagnostic code (bus) and display via the LED ERR on the module
Short-circuit / overload of the digital outputs Message in the diagnostic code
Module error during self test Message to the master

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2734840-PB IP 400 ME-ELR R-3AEnglish136 KbytesPHOENIX CONTACT-2734840-PB IP 400 ME-ELR R-3A

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or