Modular terminal block with two-stage surge protection for a floating double conductor, separate PE connection, nominal voltage: 110 V AC, for mounting on NS 35/7.5, terminal block width 6.2 mm, terminal block height: 54.6 mm

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+$59.63
20+$59.15
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height79.6 mm
Width6.2 mm
Depth54.6 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C
Degree of protectionIP20

General

Housing materialPA 6.6
Flammability rating according to UL 94V-0
Colorblack
Standards for cearances and creepage distancesIEC 60664-1
Mounting typeDIN rail: 35 mm
TypeDouble-level terminal block with PE foot – separate PE connection
Number of positions2
Direction of actionLine-Line & Line-Earth Ground

Protective circuit

IEC test classificationC1
C2
C3
D1
Nominal voltage UN110 V AC
Maximum continuous voltage UC120 V AC
Maximum continuous voltage UC (wire-wire)120 V AC
Nominal current IN300 mA (30 °C)
Operating effective current IC at UC≤ 5 µA
Residual current IPE≤ 10 µA
Nominal discharge current In (8/20) µs (Core-Core)5 kA
Nominal discharge current In (8/20) µs (Core-Earth)5 kA
Total surge current (8/20) µs10 kA
Max. discharge current Imax (8/20) µs maximum (Core-Core)5 kA
Max. discharge current Imax (8/20) µs maximum (Core-Earth)5 kA
Nominal pulse current Ian (10/1000) µs (Core-Earth)100 A
Impulse discharge current (10/350)˽µs, peak value limp500 A
Output voltage limitation at 1 kV/µs (Core-Core) spike≤ 250 V
Output voltage limitation at 1 kV/µs (Core-Earth) spike≤ 650 V
Voltage protection level Up (core-core)≤ 300 V (C2 - 10 kV / 5 kA)
≤ 250 V (C1 - 1 kV/500 A)
Voltage protection level Up (core-ground)≤ 900 V (C2 - 10 kV / 5 kA)
≤ 650 V (C1 - 1 kV/500 A)
≤ 850 V (C3 - 10 A)
≤ 900 V (C3 - 100 A)
≤ 800 V (D1 - 500 A)
Response time tA (Core-Core)≤ 1 ns
Response time tA (Core-Earth)≤ 100 ns
Input attenuation aE, sym.typ. 1.5 dB (≤ 2 MHz)
typ. 0.6 dB (≤ 500 kHz / 150 Ω)
Cut-off frequency fg (3 dB), sym. in 50 Ohm systemtyp. 15 MHz
Cut-off frequency fg (3 dB), sym. in 150 Ohm systemtyp. 8 MHz
Capacity (Core-Core)typ. 600 pF
Capacity (Core-Earth)≤ 2 pF
Resistance in series9.4 Ω 10 % (per path)
9.4 Ω
Surge protection fault messageNone
Max. required back-up fuse315 mA (T/IEC 60127-2/3)
Impulse durability (conductor-conductor)C1 - 1 kV/500 A
C2 - 10 kV/5 kA
Impulse durability (conductor-ground)C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C3 - 100 A
D1 (500 A)
Alternating current carrying capacity (conductor-conductor)0.1 A/1 s
Alternating current carrying capacity (conductor-ground)1 A/1s

Connection data

Connection methodScrew connection
Connection type INScrew terminal blocks
Connection type OUTScrew terminal blocks
Screw threadM3
Tightening torque0.8 Nm
Stripping length8 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.4 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14

Standards and Regulations

Standards/regulationsIEC 61643-21
EN 61643-21

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2858483-TT-2-PE-110ACEnglish117 KbytesPHOENIX CONTACT-2858483-TT-2-PE-110AC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or