* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2313096 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 319 (C-6-2017) |
GTIN | 4046356098816 |
Weight per Piece (excluding packing) | 240.800 g |
Custom tariff number | 85176200 |
Country of origin | DE (Germany) |
Utilization restriction | EMC: class A product, see manufacturer's declaration in the download area |
---|
Ambient temperature (operation) | -20 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Altitude | ≤ 5000 m (For restrictions see manufacturer's declaration) |
≤ 2000 m (When used in EX zone 2) | |
Degree of protection | IP20 |
Noise immunity | EN 61000-4-2 |
Transmission channels | 2 (1/1), TD, RD, half duplex |
---|---|
Bit delay | < 1 bit |
Bit distortion, input | max. ± 35 % |
Bit distortion, output | < 6.25 % |
Electrical isolation | VCC // TBUS // RS-485 (A) // RS-485 (B) |
Test voltage data interfaces | 1.5 kV |
Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
Noise emission | EN 55011 |
Net weight | 240.8 g |
Housing material | PA 6.6-FR |
Color | green |
MTBF | 1247 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
261 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) | |
MTTF | 1439 Years (SN 29500 standard, temperature 25 °C, operating cycle 21 % (5 days a week, 8 hours a day)) |
717 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day)) | |
305 Years (SN 29500 standard, temperature 40 °C, operating cycle 100 % (7 days a week, 24 hours a day)) | |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
UL, USA/Canada | 508 recognized |
Class I, Zone 2, AEx nA IIC T6 | |
Class I, Zone 2, Ex nA IIC T6 Gc X | |
Class I, Div. 2, Groups A, B, C, D |
Nominal supply voltage | 24 V DC (With UL approval) |
---|---|
Supply voltage range | 18 V DC ... 30 V DC (via pluggable COMBICON screw terminal block) |
Typical current consumption | 75 mA (24 V DC) |
Interface 1 | RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire |
---|---|
Connection method | Pluggable screw connection |
File format/coding | UART (11/10 bit switchable; NRZ) |
Data direction switching | Automatic control, min. station response time 2 bits |
Transmission medium | 2-wire twisted pair, shielded |
Transmission length | ≤ 1200 m (depends on transmission speed, bus system and cable type) |
Termination resistor | 390 Ω (Can be connected to port A and B) |
150 Ω | |
390 Ω | |
Conductor cross section solid min. | 0.2 mm² |
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 12 |
Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
---|---|
Type of test | Free fall in acc. with IEC 60068-2-32 |
Test result | 1 m |
Type of test | Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6 |
Test result | 5g, 10...150 Hz, 2.5 h, in XYZ direction |
Type of test | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
Test result | 15g, 11 ms period, half-sine shock pulse |
Noise emission | EN 55011 |
Noise immunity | EN 61000-4-2 |
Free from substances that could impair the application of coating | according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard |
Connection in acc. with standard | CUL |
Standards/regulations | EN 61000-4-2 |
Contact discharge | ± 6 kV |
Standards/regulations | EN 61000-4-3 |
Frequency range | 80 MHz ... 3 GHz |
Standards/regulations | EN 61000-4-4 |
Comments | Criterion B |
Standards/regulations | EN 61000-4-5 |
Signal | ± 1 kV |
Standards/regulations | EN 55011 |
EN 61000-4-6 | |
Designation | Air clearances and creepage distances |
Standards/regulations | DIN EN 50178, DIN EN 60950 |
Shock | 15g in all directions in acc. with IEC 60068-2-27 |
Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
Conformance | CE-compliant |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada | 508 recognized |
Class I, Zone 2, AEx nA IIC T6 | |
Class I, Zone 2, Ex nA IIC T6 Gc X | |
Class I, Div. 2, Groups A, B, C, D | |
Noxious gas test | ISA-S71.04-1985 G3 Harsh Group A |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2313096-PSI-REP-RS485W2 | 410 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.