Product successfully added to your shopping cart
MACX PL-RPSSI-2I-SP
2904962
PHOENIX_CONTACT
1
Repeater power supply
INTERFACE Components (IF)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2904962 |
---|---|
Packing unit | 1 pc |
Note | Made to Order (non-returnable) |
Catalog page | Page 138 (C-5-2017) |
GTIN | 4046356904544 |
Weight per Piece (excluding packing) | 196.080 g |
Custom tariff number | 85437090 |
Country of origin | DE (Germany) |
Ambient temperature (operation) | -20 °C ... 60 °C (Any mounting position) |
---|---|
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Maximum altitude | ≤ 2000 m |
Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
Noise immunity | EN 61000-6-2 When being exposed to interference, there may be minimal deviations. |
Signal input | Repeater power supply operation |
---|---|
Current input signal | 4 mA ... 20 mA |
Transmitter supply voltage | > 21.5 V (20 mA) |
> 21 V (23 mA) | |
Signal input | Signal conditioner operation |
Current input signal | 4 mA ... 20 mA |
Voltage drop | < 3.9 V (in input isolating amplifier operation) |
Signal output | Repeater power supply operation |
---|---|
Current output signal | 4 mA ... 20 mA (active) |
Load/output load current output | < 450 Ω (20 mA) |
< 380 Ω (23 mA) | |
Output ripple | < 20 mVrms |
Output behavior in the event of an error | 0 mA (Cable break in the input) |
≥ 23 mA (Cable short-circuit in the input) | |
Signal output | Signal conditioner operation |
Current output signal | 4 mA ... 20 mA (active) |
Load/output load current output | < 450 Ω (20 mA) |
< 380 Ω (23 mA) | |
Output ripple | < 20 mVrms |
Output behavior in the event of an error | 0 mA (Cable break in the input) |
≥ 23 mA (Cable short-circuit in the input) |
Designation | Repeater power supply operation |
---|---|
Nominal supply voltage | 24 V DC |
Supply voltage range | 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) |
Max. current consumption | < 75 mA (24 V DC) |
Power dissipation | < 1.45 W (24 V DC/ 20 mA) |
Designation | Signal conditioner operation |
Nominal supply voltage range | 19.2 V DC ... 30 V DC (24 V DC -20%...+25%) |
Max. current consumption | < 46 mA (24 V DC / 20 mA) |
Power dissipation | < 1.2 W (24 V DC/ 20 mA) |
Conductor cross section solid min. | 0.2 mm² |
---|---|
Conductor cross section solid max. | 1.5 mm² |
Conductor cross section flexible min. | 0.2 mm² |
Conductor cross section flexible max. | 1.5 mm² |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG max. | 16 |
Stripping length | 8 mm |
Connection method | Push-in connection |
No. of channels | 1 |
---|---|
Maximum transmission error | < 0.1 % (of final value) |
Transmission error, typical | < 0.05 % (of final value) |
Maximum temperature coefficient | < 0.01 %/K |
Step response (10-90%) | 1.3 ms (for jump 4 mA ... 20 mA, typical) |
Status display | Green LED (PWR supply voltage) |
Flammability rating according to UL 94 | V0 |
Electromagnetic compatibility | Conformance with EMC directive |
Housing material | PA 6.6-FR |
Color | yellow |
Designation | Input/output/power supply |
Electrical isolation | 300 Vrms (Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1)) |
2.5 kV (50 Hz, 1 min., test voltage) | |
Designation | Output 1/output 2 |
Electrical isolation | 1.5 kV AC (50 Hz, 1 min., test voltage) |
Conformance | CE-compliant, additionally EN 61326 |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada | UL 61010 Listed |
Class I, Div. 2, Groups A, B, C, D T4 | |
Class I, Zone 2, Group IIC T4 | |
SIL | 2 |
Designation | Electromagnetic RF field |
---|---|
Standards/regulations | EN 61000-4-3 |
Typical deviation from the measuring range final value | 3 % |
Designation | Fast transients (burst) |
Standards/regulations | EN 61000-4-4 |
Typical deviation from the measuring range final value | 3 % |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Typical deviation from the measuring range final value | 3 % |
Electromagnetic compatibility | Conformance with EMC directive |
---|---|
Designation | Electromagnetic RF field |
Standards/regulations | EN 61000-4-3 |
EN 61000-4-4 | |
Designation | Conducted interferences |
Standards/regulations | EN 61000-4-6 |
Flammability rating according to UL 94 | V0 |
Conformance | CE-compliant, additionally EN 61326 |
ATEX | II 3 G Ex nA IIC T4 Gc X |
UL, USA/Canada | UL 61010 Listed |
Class I, Div. 2, Groups A, B, C, D T4 | |
Class I, Zone 2, Group IIC T4 |
REACh SVHC | Lead 7439-92-1 |
---|---|
China RoHS | Environmentally Friendly Use Period = 50 |
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX INTERFACE TECHNOLOGY AND SWITCHING DEVICES EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2904962-MACX PL-RPSSI-2I-SP | 124 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.