MCR-FL-T-LP-I 2864561 PHOENIX CONTACT Temperature measuring transducer View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MCR-FL-T-LP-I 2864561 PHOENIX CONTACT Temperature measuring transducer

MCR-FL-T-LP-I

2864561

PHOENIX_CONTACT

Temperature measuring transducer

More details


INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2864561
Packing unit1 pc
Catalog pagePage 196 (C-5-2017)
GTIN4017918899820
Weight per Piece (excluding packing)105.600 g
Custom tariff number85437090
Country of originDE (Germany)

Dimensions

Width12.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 85 °C

Input data

Configurable/programmableYes, programmable
Sensor types (RTD) that can be usedPt, Ni (100, 500, 1000); minimum measurement range 10 K
Sensor types that can be used (TC)B, C, D, E, J, K, L, N, R, S, T, U; minimum measurement range 50 K/500 K
Linear resistance measuring rangeResistance-type sensor from 10 Ω to 400 Ω and from 10 Ω to 2000 Ω; minimum measurement range 10 Ω/100 Ω
Connection technology2, 3, 4-wire

Output data

Output nameCurrent output
Number of outputs1
Configurable/programmableYes
Current output signal4 mA ... 20 mA
20 mA ... 4 mA
Output current with wire break≤ 3.6 mA or ≥ 21 mA (adjustable)
Output current with short-circuit≤ 3.6 mA or ≥ 21 mA (adjustable, not for thermocouples)
Output current range with overrange/underrange≤ 20.5 mA / ≥ 3.8 mA (linear increase/decrease)
Load/output load current outputmax (Vsupply-12 V) / 0.023 A (current output)

Power supply

DesignationLoop-powered
Supply voltage range12 V DC ... 35 V DC
Max. current consumption< 3.5 mA

Connection data

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length8 mm
Screw threadM3

General

Transmission error resistance thermometer0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000)
Transmission error thermocouplestyp. 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R)
Transmission error resistance-type sensor± 0.1 Ω (10...400 Ω), ± 1.5 Ω (10...2000 Ω)
Transmission error voltage sensor± 20 µV (-10...100 mV)
Step response (10-90%)< 2 s
Switch-on delay4 s
Test voltage input/output2 kV (50 Hz, 1 min.)
Noise emissionEN 61326-1 (IEC 61326) and NAMUR NE 21
Noise immunityEN 61326-1 (IEC 61326) and NAMUR NE 21
Colorgreen
Housing materialPolyamide PA non-reinforced
Mounting positionany
ConfigurationUsing MCR-PI-CONF-WIN configuration software package
ConformanceCE-compliant
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D

Standards and Regulations

Noise emissionEN 61326-1 (IEC 61326) and NAMUR NE 21
Noise immunityEN 61326-1 (IEC 61326) and NAMUR NE 21
Connection in acc. with standardCUL
ConformanceCE-compliant
UL, USA/CanadaClass I, Div. 2, Groups A, B, C, D

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.