MINI MCR-SL-UI-REL 2864480 PHOENIX CONTACT MCR limit value switch, with adjustable hysteresis and delay time.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MINI MCR-SL-UI-REL 2864480 PHOENIX CONTACT MCR limit value switch, with adjustable hysteresis and delay time..

MINI MCR-SL-UI-REL

2864480

PHOENIX_CONTACT

Available

Ship on today

MCR limit value switch, with adjustable hysteresis and delay time, with screw connection

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$163.30
2+$159.01
3+$156.88
4+$155.52
6+$154.47
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The 6.2 mm wide configurable 3-way threshold value switch MINI MCR-SL-UI-REL... is used to control and monitor analog standard signals.

On the input side, the analog standards signals 0...20 mA or 0...10 V per DIP switch can be set. On the output side, a relay with PDT contact is available. The switching thresholds are set via potentiometer.

The DIP switches located on the side of the housing have the following functions:

– Configuration of the switching hysteresis,

– Configuration of the operating and closed circuit current behavior,

– Setting of relay pickup times

– Setting of dropout delay

The relay status is indicated by a yellow LED on the front of the housing.

Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.

Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Number of inputs1
Voltage input signal0 V ... 10 V
Current input signal0 mA ... 20 mA
Max. input voltage30 V
Max. input current100 mA
Input resistance of voltage input> 100 kΩ
Input resistance current input50 Ω

Output data

Number of outputs1

Switching output

Output nameRelay output
Contact type1 PDT
Contact materialAgSnO2, hard gold-plated
Maximum switching voltage250 V AC
240 V AC (UL)
Limiting continuous current2 A
Setting range of the response delay0 s ... 10 s (0 s; 1 s; 2 s; 3 s; 4 s; 6 s; 8 s; 10 s)
Internal hysteresis0.1 %; 1 %; 2.5 %; 5 %

Power supply

Nominal supply voltage24 V DC ±15 %
Supply voltage range19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715))
Max. current consumption< 14 mA (at 24 V DC)
Power consumption< 330 mW (at 24 V DC)

Connection data

Connection methodScrew connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.26
Conductor cross section AWG max.12
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length12 mm
Screw threadM3

General

No. of channels1
Maximum temperature coefficient< 0.02 %/K
Switching point accuracy< 0.05 %
Electrical isolationBasic insulation according to EN 61010
Overvoltage categoryII
Pollution degree2
Rated insulation voltage50 V AC/DC
Test voltage input/power supply1.5 kV AC (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Colorgreen
Housing materialPBT
Mounting positionany
Assembly instructionsThe T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
ConformanceCE-compliant
ATEXEx II 3 G Ex nA nC IIC T4 Gc X
UL, USAClass I, Zone 2, AEx nA nC IIC T5
UL, USA / CanadaUL 508 Recognized
UL, CanadaClass I, Zone 2, Ex nA nC IIC T5 Gc
GLGL EMC 2 D

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value5 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value5 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value5 %

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2864480-MINI MCR-SL-UI-RELEnglish136 KbytesPHOENIX CONTACT-2864480-MINI MCR-SL-UI-REL