FLM TEMP 4 RTD M12 2736819 PHOENIX CONTACT The local bus device has 4 inputs for resistive temperature senso.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

FLM TEMP 4 RTD M12 2736819 PHOENIX CONTACT The local bus device has 4 inputs for resistive temperature senso..

FLM TEMP 4 RTD M12

2736819

PHOENIX_CONTACT

Available

Ship on today

The local bus device has 4 inputs for resistive temperature sensors. Functions: 180 µs A/D conversion time, measured value output in 16-bit values, 500 kbaud/2 Mbaud selection, PCP configuration, short-circuit/overload protection, M12 fast connection technology.

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width70 mm
Height178 mm
Depth50 mm
Drill hole spacing168 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (storage/transport)95 %
Air pressure (operation)80 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP65/IP67

General

Net weight280 g
Mounting typeWall mounting

Interfaces

DesignationFieldline local bus
Connection methodM12 connector, B-coded
Transmission speed500 kBit/s / 2 MBit/s
Transmission physicsCopper

Power supply for module electronics

Supply voltage24 V DC
Supply voltage range18 V DC ... 30 V DC (including ripple)

Fieldline potentials

Voltage supply UL24 V DC
Power supply at ULmax. 4 A
Current consumption from ULmax. 100 mA (At 2 Mbaud)
typ. 70 mA
Voltage supply US24 V DC
Power supply at USmax. 4 A
Current consumption from UStyp. 5 mA (plus power supply for sensors)
max. 400 mA

Analog inputs

Number of inputsmax. 4 (for resistance temperature detectors)
Connection methodM12 connector
2, 3, 4-wire (shielded)
Number of inputsmax. 4 (for resistance temperature detectors)
Connection methodM12 connector
2, 3, 4-wire (shielded)
Sensor types (RTD) that can be usedPt, Ni, KTY sensors, linear resistors
Process data updateDependent on the connection method
Input filter time4.1 ms (default setting or 0.6 ms; adjustable for each channel)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2736819-FLM TEMP 4 RTD M12English111 KbytesPHOENIX CONTACT-2736819-FLM TEMP 4 RTD M12

Reviews (0)