PWT 100-800AC-FM 2800531 PHOENIX CONTACT Lightning/surge arrester, according to type 1/2 / class I/II, for 3.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PWT 100-800AC-FM 2800531 PHOENIX CONTACT Lightning/surge arrester, according to type 1/2 / class I/II, for 3..

PWT 100-800AC-FM

2800531

PHOENIX_CONTACT

Available

Ship on today

Lightning/surge arrester, according to type 1/2 / class I/II, for 3-phase power supply networks with combined PE and N installed in one conductor (L1, L2, L3, PEN).

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height191 mm
Width176 mm
Depth280 mm
Horizontal pitch10 Div.

Ambient conditions

Degree of protectionIP20
IP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
-40 °C ... 55 °C (serial through wiring ≥ 35 mm²)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 4000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 150 Hz / 2.5 h / X, Y, Z)
4g (5 ... 100 Hz / X, Y, Z - according to GL )

General

IEC power supply systemTN-C
IT
Housing materialDie-cast aluminum, salt water resistant
Flammability rating according to UL 94V-2
Colorsilver gray
gray
Standards for cearances and creepage distancesDIN EN 60664-1
EN 61643-11
Mounting typeScrew mounting
TypeInstallation module
Number of positions3
Surge protection fault messageOptical, remote indicator contact
Direction of action3L-PEN

Protective circuit

IEC test classificationI / II
T1 / T2
T1
I
EN typeT1 / T2
T1
Lightning protection classI
Nominal voltage UN690 V AC
Maximum continuous operating voltage UC (L-PE)800 V AC
UT (TOV-proof)1500 V AC (5 sec.)
1960 V AC (200 ms)
Nominal frequency fN50 Hz (60 Hz)
Rated load current IL150 A (Serial through wiring with 50 mm²)
Residual current IPE≤ 20 µA
Standby power consumption PC≤ 48 mVA
Max. discharge current Imax (8/20) µs maximum (L-PE)100 kA
Nominal discharge current In (8/20) µs (L-PE)35 kA
Impulse discharge current (10/350) µs (L-PE), charge17.5 As
Impulse discharge current (10/350) µs (L-PE), specific energy305 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp35 kA
Front of wave sparkover voltage at 6 kV (1.2/50) µs (L-PE)≤ 4.5 kV
Voltage protection level Up (L-PE)≤ 4.5 kV
Residual voltage (L-PE)≤ 2.7 kV
≤ 2.5 kV (at 20 kA)
≤ 2.3 kV (at 10 kA)
≤ 2.2 kV (at 5 kA)
≤ 2.1 kV (at 3 kA)
Response time (L-PE)≤ 100 ns
Max. backup fuse with branch wiring400 A (gG; 2 x 50 mm²)
800 A (aR (only up to limp = 25 kA))
Max. backup fuse with V-type through wiring125 A (gG; ≥ 35 mm²)
Short-circuit resistance IP with max. backup fuse (effective)50 kA
Short-circuit current rating ISCCR50 kA
Follow current interrupt rating Ifi (L-PE)50 kA

Connection, protective circuit

Connection nameDouble terminal point
Connection methodScrew connection
Screw threadM6
Tightening torque8.5 Nm
75 lbf-in. (UL)
Stripping length24 mm
Conductor cross section flexible min.16 mm²
Conductor cross section flexible max.50 mm²
Conductor cross section solid min.16 mm²
Conductor cross section solid max.50 mm²
Conductor cross section AWG6 ... 1/0
6 ... 1/0 (UL)
Connection namePE conductor connection
Connection methodRing cable lug
M10 hexagonal head screw (ISO 4017/DIN 933)
Screw threadM10
Tightening torque20 Nm
175 lbf-in. (UL)
Conductor cross section flexible min.16 mm²
Conductor cross section flexible max.95 mm²
Conductor cross section solid min.16 mm²
Conductor cross section solid max.95 mm²
Conductor cross section AWG6 ... 3/0
3/0 (UL)

Remote indicator contact

Connection nameRemote indicator contact
Switching function2x N/C contacts, 1-pos.
Screw threadM3
Tightening torque0.55 Nm
5 lbf-in. ... 7 lbf-in. (UL)
Stripping length7 mm
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG24 ... 12
24 ... 12 (UL)
Maximum operating voltage Umax. AC30 V AC
Maximum operating voltage Umax DC30 V DC
Max. operating current Imax1.5 A AC
1.5 A DC

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2800531-PWT 100-800AC-FMEnglish473 KbytesPHOENIX CONTACT-2800531-PWT 100-800AC-FM

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or