Key Commercial Data

Orderkey2800531
Packing unit1 pc
Catalog pagePage 40 (C-4-2017)
GTIN4046356570688
Weight per Piece (excluding packing)10,845.000 g
Custom tariff number85363010
Country of originDE (Germany)

Dimensions

Height191 mm
Width176 mm
Depth280 mm
Horizontal pitch10 Div.

Ambient conditions

Degree of protectionIP20 (only when all terminal points are used)
Ambient temperature (operation)-40 °C ... 80 °C
-40 °C ... 55 °C (serial through wiring ≥ 35 mm²)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Altitude≤ 4000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %
Shock (operation)25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)5g (10 ... 150 Hz / 2.5 h / X, Y, Z)
4g (5 ... 100 Hz / X, Y, Z - according to GL )

General

IEC test classificationI / II
T1 / T2
T1
I
EN typeT1 / T2
T1
IEC power supply systemTN-C
IT
Mode of protectionL-PE
Mounting typeScrew mounting
Colorsilver gray
gray
Housing materialDie-cast aluminum, salt water resistant
Degree of pollution3
Flammability rating according to UL 94V-2
TypeInstallation module
Number of positions3
Surge protection fault messageOptical, remote indicator contact

Additional descriptions

NoteAssembling: Two 8 mm screws with 8 Nm on an isolated or grounded surface
Long-wave surge current 2 ms in accordance with IEC 60099-4: 250 x 1.0 kA; 500 x 0.5 kA.

Protective circuit

Nominal voltage UN690 V AC
554/960 V AC (TN-C)
690 V AC (IT)
Nominal frequency fN50 Hz (60 Hz)
Maximum continuous operating voltage UC(L-PE)800 V AC
Rated load current IL150 A (Serial through wiring with 50 mm²)
Residual current IPE≤ 20 µA
Standby power consumption PC≤ 48 mVA
Nominal discharge current In(8/20) µs (L-PE)35 kA
Maximum discharge current Imax(8/20) µs (L-PE)100 kA
Impulse discharge current (10/350) µs (L-PE), charge17.5 As
Impulse discharge current (10/350) µs (L-PE), specific energy305 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp35 kA
Total discharge current Itotal(10/350) µs100 kA
Follow current interrupt rating Ifi(L-PE)50 kA
Short-circuit current rating ISCCR50 kA
Voltage protection level Up(L-PE)≤ 4.5 kV
Residual voltage Ures(L-PE)≤ 2.7 kV (at In)
≤ 2.5 kV (at 20 kA)
≤ 2.3 kV (at 10 kA)
≤ 2.2 kV (at 5 kA)
≤ 2.1 kV (at 3 kA)
TOV behavior at UT(L-PE)1960 V AC (200 ms / withstand mode)
1500 V AC (5 s / withstand mode)
Response time tA(L-PE)≤ 100 ns
Max. backup fuse with V-type through wiring125 A (gG at ≥35 mm²)
Max. backup fuse with branch wiring400 A (gG at 2x 50 mm²)
800 A (aR (only up to Iimp= 25 kA))

Indicator/remote signaling

Switching function2x N/C contacts, 1-pos.
Operating voltage30 V AC
30 V DC
Operating current1.5 A AC
1.5 A DC
Screw threadM3
Tightening torque0.55 Nm
Stripping length7 mm
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 12

Supply status indicator / remote signaling

Operating voltage19.2 V AC/DC ... 30 V AC/DC
Operating current7 mA AC/DC ... 13 mA AC/DC
Rated current10 mA AC/DC
Max. required back-up fuse1 A (e.g. T to IEC 127-2/III)
Immunity to interference according to IEC 61000-4-5 (core-core)1 kV
Immunity to interference according to IEC 61000-4-5 (core-ground)6 kV

Connection data

Connection nameDouble terminal point
Connection methodScrew connection
Screw threadM6
Tightening torque8.5 Nm
Stripping length24 mm
Conductor cross section flexible16 mm² ... 50 mm²
Conductor cross section solid16 mm² ... 50 mm²
Conductor cross section AWG6 ... 1/0
Connection namePE conductor connection
Connection methodRing cable lug
Tightening torque20 Nm
Conductor cross section flexible16 mm² ... 95 mm²
Conductor cross section solid16 mm² ... 95 mm²
Conductor cross section AWG6 ... 3/0

UL specifications

SPD Type4CA
Maximum continuous operating voltage MCOV (L-L)800 V AC
Maximum continuous operating voltage MCOV (L-G)800 V AC
Nom. voltage690 V AC
400 V AC
Mode of protectionL-L
L-G
Power distribution systemWye
Delta
Nominal frequency60 Hz
Measured limiting voltage MLV (L-L)8750 V
Measured limiting voltage MLV (L-G)4370 V
Nominal discharge current In(L-L)20 kA
Nominal discharge current In(L-G)20 kA

UL indicator/remote signaling

Operating voltage30 V AC
30 V DC
Operating current1.5 A AC
1.5 A DC
Tightening torque5 lbf-in. ... 7 lbf-in.
Conductor cross section AWG24 ... 12

UL connection data

Connection nameDouble terminal point
Conductor cross section AWG1/0 ... 6
Tightening torque75 lbf-in.

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.