Product successfully added to your shopping cart
PWT 100-800AC-FM
2800531
PHOENIX_CONTACT
1
Lightning/surge arrester type 1/2
Trabtech (TT)
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Orderkey | 2800531 |
---|---|
Packing unit | 1 pc |
Catalog page | Page 40 (C-4-2017) |
GTIN | 4046356570688 |
Weight per Piece (excluding packing) | 10,845.000 g |
Custom tariff number | 85363010 |
Country of origin | DE (Germany) |
Degree of protection | IP20 (only when all terminal points are used) |
---|---|
Ambient temperature (operation) | -40 °C ... 80 °C |
-40 °C ... 55 °C (serial through wiring ≥ 35 mm²) | |
Ambient temperature (storage/transport) | -40 °C ... 80 °C |
Altitude | ≤ 4000 m (amsl (above mean sea level)) |
Permissible humidity (operation) | 5 % ... 95 % |
Shock (operation) | 25g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
Vibration (operation) | 5g (10 ... 150 Hz / 2.5 h / X, Y, Z) |
4g (5 ... 100 Hz / X, Y, Z - according to GL ) |
IEC test classification | I / II |
---|---|
T1 / T2 | |
T1 | |
I | |
EN type | T1 / T2 |
T1 | |
IEC power supply system | TN-C |
IT | |
Mode of protection | L-PE |
Mounting type | Screw mounting |
Color | silver gray |
gray | |
Housing material | Die-cast aluminum, salt water resistant |
Degree of pollution | 3 |
Flammability rating according to UL 94 | V-2 |
Type | Installation module |
Number of positions | 3 |
Surge protection fault message | Optical, remote indicator contact |
Note | Assembling: Two 8 mm screws with 8 Nm on an isolated or grounded surface |
---|---|
Long-wave surge current 2 ms in accordance with IEC 60099-4: 250 x 1.0 kA; 500 x 0.5 kA. |
Nominal voltage UN | 690 V AC |
---|---|
554/960 V AC (TN-C) | |
690 V AC (IT) | |
Nominal frequency fN | 50 Hz (60 Hz) |
Maximum continuous operating voltage UC(L-PE) | 800 V AC |
Rated load current IL | 150 A (Serial through wiring with 50 mm²) |
Residual current IPE | ≤ 20 µA |
Standby power consumption PC | ≤ 48 mVA |
Nominal discharge current In(8/20) µs (L-PE) | 35 kA |
Maximum discharge current Imax(8/20) µs (L-PE) | 100 kA |
Impulse discharge current (10/350) µs (L-PE), charge | 17.5 As |
Impulse discharge current (10/350) µs (L-PE), specific energy | 305 kJ/Ω |
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp | 35 kA |
Total discharge current Itotal(10/350) µs | 100 kA |
Follow current interrupt rating Ifi(L-PE) | 50 kA |
Short-circuit current rating ISCCR | 50 kA |
Voltage protection level Up(L-PE) | ≤ 4.5 kV |
Residual voltage Ures(L-PE) | ≤ 2.7 kV (at In) |
≤ 2.5 kV (at 20 kA) | |
≤ 2.3 kV (at 10 kA) | |
≤ 2.2 kV (at 5 kA) | |
≤ 2.1 kV (at 3 kA) | |
TOV behavior at UT(L-PE) | 1960 V AC (200 ms / withstand mode) |
1500 V AC (5 s / withstand mode) | |
Response time tA(L-PE) | ≤ 100 ns |
Max. backup fuse with V-type through wiring | 125 A (gG at ≥35 mm²) |
Max. backup fuse with branch wiring | 400 A (gG at 2x 50 mm²) |
800 A (aR (only up to Iimp= 25 kA)) |
Switching function | 2x N/C contacts, 1-pos. |
---|---|
Operating voltage | 30 V AC |
30 V DC | |
Operating current | 1.5 A AC |
1.5 A DC | |
Screw thread | M3 |
Tightening torque | 0.55 Nm |
Stripping length | 7 mm |
Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
Conductor cross section solid | 0.2 mm² ... 2.5 mm² |
Conductor cross section AWG | 24 ... 12 |
Operating voltage | 19.2 V AC/DC ... 30 V AC/DC |
---|---|
Operating current | 7 mA AC/DC ... 13 mA AC/DC |
Rated current | 10 mA AC/DC |
Max. required back-up fuse | 1 A (e.g. T to IEC 127-2/III) |
Immunity to interference according to IEC 61000-4-5 (core-core) | 1 kV |
Immunity to interference according to IEC 61000-4-5 (core-ground) | 6 kV |
Connection name | Double terminal point |
---|---|
Connection method | Screw connection |
Screw thread | M6 |
Tightening torque | 8.5 Nm |
Stripping length | 24 mm |
Conductor cross section flexible | 16 mm² ... 50 mm² |
Conductor cross section solid | 16 mm² ... 50 mm² |
Conductor cross section AWG | 6 ... 1/0 |
Connection name | PE conductor connection |
Connection method | Ring cable lug |
Tightening torque | 20 Nm |
Conductor cross section flexible | 16 mm² ... 95 mm² |
Conductor cross section solid | 16 mm² ... 95 mm² |
Conductor cross section AWG | 6 ... 3/0 |
SPD Type | 4CA |
---|---|
Maximum continuous operating voltage MCOV (L-L) | 800 V AC |
Maximum continuous operating voltage MCOV (L-G) | 800 V AC |
Nom. voltage | 690 V AC |
400 V AC | |
Mode of protection | L-L |
L-G | |
Power distribution system | Wye |
Delta | |
Nominal frequency | 60 Hz |
Measured limiting voltage MLV (L-L) | 8750 V |
Measured limiting voltage MLV (L-G) | 4370 V |
Nominal discharge current In(L-L) | 20 kA |
Nominal discharge current In(L-G) | 20 kA |
Operating voltage | 30 V AC |
---|---|
30 V DC | |
Operating current | 1.5 A AC |
1.5 A DC | |
Tightening torque | 5 lbf-in. ... 7 lbf-in. |
Conductor cross section AWG | 24 ... 12 |
Connection name | Double terminal point |
---|---|
Conductor cross section AWG | 1/0 ... 6 |
Tightening torque | 75 lbf-in. |
China RoHS | Environmentally Friendly Use Period = 50 |
---|---|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX PROTECTION EN.pdf | 27 Mbytes | |
PHOENIX CONTACT-2800531-PWT 100-800AC-FM | 473 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.