INTERFACE Components (IF)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $182.85
Unit price: $182.85

Quantity Price
1+$182.85
2+$158.82
3+$154.10
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2865997
Packing unit1 pc
Catalog pagePage 132 (C-5-2017)
GTIN4046356466981
Weight per Piece (excluding packing)134.100 g
Custom tariff number85437090
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Width12.5 mm
Height112.5 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 EN 61326

Input data

Non-load voltage~ 8 V DC
Switching points (attenuated)< 1.2 mA (blocking)
Switching points (unattenuated)> 2.1 mA (conductive)
Available input sourcesNAMUR proximity sensors (EN 60947-5-6)
Short-circuit current~ 8 mA
Switching hysteresis< 0.2 mA
Line fault detectionBreak 0.05 mA < IIN < 0.35 mA
Short circuit 100 Ω < RSensor < 360 Ω

Output data

Switching outputRelay output
Contact type1 PDT
Contact materialAgSnO2, hard gold-plated
Maximum switching voltage250 V AC (2 A)
120 V DC (0.2 A)
30 V DC (2 A)
Maximum switching capacity500 VA
Mechanical service life107cycles
Switching frequency≤ 20 Hz (without load)

Power supply

Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC -20%...+25%)
Max. current consumption21 mA (24 V DC)
Power dissipation< 650 mW
Power consumption< 650 mW

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

No. of channels1
Status displayGreen LED (supply voltage)
LED yellow (switching state)
Red LED (line errors)
Flammability rating according to UL 94V0
Degree of pollution2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC directive
Interference emissionEN 61000-6-4
Housing materialPA 6.6-FR
Colorgray
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/output/supply, DIN rail connector
Electrical isolation300 Vrms(Rated insulation voltage (overvoltage category II; degree of pollution 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationOutput/input, supply, TBUS
Electrical isolation300 Vrms(Rated insulation voltage (overvoltage category III; degree of pollution 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/supply, DIN rail connector
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326-1
ATEX II 3 G Ex nA nC IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
SIL2

Safety characteristic data

Integrity requirementIEC 61508 - Low demand
DesignationNon-inverted operation
Equipment typeType A
Safety Integrity Level (SIL)2
Safe Failure Fraction (SFF)78 %
λSU2.49 x 10-7(249 FIT)
λSD6 x 10-9(6 FIT)
λDU6.4 x 10-8(64 FIT)
λDD7 x 10-9(7 FIT)
Probability of a hazardous failure on demand (PFDAVG)3.09 x 10-4(1 year)
6.17 x 10-4(2 years)
1.54 x 10-3(5 years)
Diagnostic coverage (DC)DCS= 2.4 %, DCD= 9 %
Integrity requirementIEC 61508 - Low demand
DesignationInverted operation
Equipment typeType A
Safety Integrity Level (SIL)2
Safe Failure Fraction (SFF)78 %
λSU2.48 x 10-7(248 FIT)
λSD1 x 10-9(1 FIT)
λDU6.2 x 10-8(62 FIT)
λDD6 x 10-9(6 FIT)
Probability of a hazardous failure on demand (PFDAVG)3.01 x 10-4(1 year)
6.02 x 10-4(2 years)
1.5 x 10-3(5 years)
Diagnostic coverage (DC)DCS= 0.4 %, DCD= 8 %
Safety Integrity Level (SIL)1

Standards and Regulations

Electromagnetic compatibilityConformance with EMC directive
Noise emissionEN 61000-6-4
Flammability rating according to UL 94V0
ConformanceCE-compliant, additionally EN 61326-1
ATEX II 3 G Ex nA nC IIC T4 Gc X
UL, USA/CanadaUL 508 Listed
UL 61010 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4
DNV GL-TemperatureB
DNV GL-HumidityB
DNV GL-VibrationA
DNV GL-EMCB
DNV GL-EnclosureRequired protection according to the Rules shall be provided upon installation on board

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.