MACX MCR-SL-RPSSI-I-SP 2924207 PHOENIX CONTACT Repeater power supply and input isolating amplifier, HART. Tr.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-SL-RPSSI-I-SP 2924207 PHOENIX CONTACT Repeater power supply and input isolating amplifier, HART. Tr..

MACX MCR-SL-RPSSI-I-SP

2924207

PHOENIX_CONTACT

Available

Ship on today

Repeater power supply and input isolating amplifier, HART. Transfers supplied or active 0/4 - 20 mA signals to a load (active or passive). 3-way electrical isolation, SIL 2 according to IEC 61508.

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$204.05
2+$199.02
3+$196.52
4+$194.98
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width12.5 mm
Height116 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Degree of protectionIP20

Input data

Signal inputActive current input
Current input signal4 mA ... 20 mA
Transmitter supply voltage> 21.5 V (20 mA)
> 20.8 V (24 mA)
Signal inputPassive current input
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
Voltage drop< 3.5 V

Output data

Signal outputCurrent output (active and passive)
Current output signal4 mA ... 20 mA (active)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 1000 Ω (20 mA)
< 825 Ω (24 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 22.5 mA (Cable short-circuit in the input)
Signal outputCurrent output (active and passive)
Current output signal0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 1000 Ω (20 mA)
< 825 Ω (24 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)

Power supply

DesignationRepeater power supply operation
Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%))
Max. current consumption< 76 mA (24 V DC / 20 mA / 1000 )
Power consumption< 1.1 W (24 V DC / 20 mA)
< 1.8 W (20 mA / 1000 )

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Connection methodPush-in connection

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Step response (10-90%)< 200 µs (for jump 4 mA ... 20 mA, load 600)
< 600 µs (for jump 0 mA ... 20 mA, load 600)
Status displayGreen LED (supply voltage)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Housing materialPA 66-FR
Colorgreen
DesignationInput/output/power supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326
ATEXEx II 3 G Ex nA II T4 Gc X
UL, USA / CanadaUL 61010 Listed
UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC T4

Data communication (bypass)

HART functionYes
Protocols supportedHART

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2924207-MACX MCR-SL-RPSSI-I-SPEnglish156 KbytesPHOENIX CONTACT-2924207-MACX MCR-SL-RPSSI-I-SP