Inline extension module, for brake control in conjunction with Inline power level terminals, brake module for 440 V DC or 440 V AC brakes

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The brake module is a passive, electronic brake control switch which can be snapped on the power-level terminal block using a 3-pos. inverted COMBICON plug.

The connection to the brake is made using a 2-pos. COMBICON plug with a connection cross section of up to 2.5 mm².

Dimensions

Width55 mm
Height57 mm
Depth16 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 55 °C (permitted)
Ambient temperature (storage/transport)-25 °C ... 85 °C (permitted)
Permissible humidity (operation)75 % ... 85 % (75% average, 85% seldom)
Permissible humidity (storage/transport)75 % ... 85 % (75% average, 85% seldom)
Air pressure (operation)80 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)

General

Protection classI, IEC 61140, EN 61140, VDE 0140-1
Weight91 g

Electrical isolation

Test section24 V supply (US), GND, brake control/protective earth ground (PE) 500 V AC 50 Hz 1 min.
24 V supply (US), GND, brake control/brake output 500 V AC 50 Hz 1 min.
Brake output/protective earth ground (PE) 500 V AC 50 Hz 1 min.

Brake module

Connection nameConnection to the power-level terminal block
Connection method3-pos. inverted COMBICON connectors (X8)
Control voltage24 V DC (= Us from the power-level terminal block)
Control current17 mA
Active current limitationThrough resistor

Brake to be connected

Connection nameConnection of the brake to the brake module
Connection method2-pos. COMBICON connectors (X9)
Cross section2.5 mm² (maximum conductor cross section)
Protective circuitSurge voltage suppression > 750 V
Type of contactUnpolarized semiconductor switch
Connection voltage20 V AC ... 440 V AC (no tolerances permitted)
12 V DC ... 440 V DC (no tolerances permitted)
Residual voltage3.4 V (maximum)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2727394-IB IL 400 BREnglish104 KbytesPHOENIX CONTACT-2727394-IB IL 400 BR

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or