ILC 191 ME/INC 2700075 PHOENIX CONTACT Inline controller with integrated pulse/direction/PWM interface, RS-4.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ILC 191 ME/INC 2700075 PHOENIX CONTACT Inline controller with integrated pulse/direction/PWM interface, RS-4..

ILC 191 ME/INC

2700075

PHOENIX_CONTACT

Available

Ship on today

Inline controller with integrated pulse/direction/PWM interface, RS-485/RS-422, fast counters, and incremental encoder inputs, with programming options according to IEC 61131-3

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$496.36
2+$489.59
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

With the ILC 191 ME/INC, the highly modular Inline controller range from Phoenix Contact has been extended to include a powerful compact controller. The controller already has 8 digital inputs and 4 outputs, a two-channel pulse/direction/PWM interface, an integrated RS-232 interface and RS-485/RS-422 interface, a two-channel fast counter with a cut-off frequency of up to 200 kHz, and two incremental encoder inputs for asymmetrical incremental encoders. With direct integration into the Inline automation system, the compact controller is highly modular and can be adapted to the relevant application requirements. Its integrated Ethernet interfaces enable parameterization and programming using PC WORX automation software according to IEC 61131, and it can also exchange data with OPC servers simultaneously and communicate with TCP/IP-compatible devices.

Dimensions

Width164 mm
Height136.8 mm
Depth71.5 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above mean sea level)
Shock25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation)5g

Control system

Programming toolPC WORX / PC WORX EXPRESS
Diagnostics toolDIAG+
Configuration toolConfig+ Version 1.01 or later

Mechanical design

Weight285 g
Diagnostics displayNo
Controller redundancyNo

Data interfaces

InterfaceINTERBUS local bus (master)
Connection methodInline data jumper
Transmission speed500 kBaud / 2 MBaud (can be switched)
InterfaceParameterization/operation/diagnostics
Connection methodRS-232-C, 6-pos. MINI-DIN socket (PS/2), Ethernet 10/100 (RJ45)
Transmission speedmax. 115,2 kBit/s
Connection method4-pos. for full duplex
2-pos. for half duplex
InterfaceEthernet 10Base-T/100Base-TX
Connection methodRJ45 socket
Transmission speed10/100 MBit/s

PROFINET

Device functionPROFINET device

Power supply

Typical current consumption350 mA
Supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC
Residual ripple± 5 %
Power dissipationmax. 8.4 W

Fieldbus function

Amount of process datamax. 4096 Bit (INTERBUS)
max. 32768 Bit (internal Modbus Client)
Number of supported devicesmax. 128
Number of local bus devices that can be connectedmax. 63 (observe current consumption)
Number of devices with parameter channelmax. 24
Number of supported branch terminals with remote bus branchmax. 3

Direct I/Os

Input nameDigital inputs
Number of inputs8
Connection methodInline potential distributor
Description of the inputEN 61131-2 type 1 NPN/PNP
Output nameDigital outputs
Number of outputs4
Connection method2, 3, 4-wire
Maximum output current per channel500 mA
Without analog inputyes
Without analog outputyes
Without pulse direction outputNo
Number of pulse direction outputs2 (can be used as an alternative to pulse width modulation)
Output voltage5 V
Limit frequency150 kHz
Without counter inputNo
Number of inputs2
Input voltage range "1" signal5 V DC ... 24 V DC
Input frequency200 kHz
Number of inputs2 (3-coil, asymmetrical)
Input voltage range "1" signal5 V DC ... 24 V DC

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2700075-ILC 191 ME/INCEnglish119 KbytesPHOENIX CONTACT-2700075-ILC 191 ME/INC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields