ILC 200 UNI-PAC 2862291 PHOENIX CONTACT Inline controller with an INTERBUS local bus interface for the Inlin.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ILC 200 UNI-PAC 2862291 PHOENIX CONTACT Inline controller with an INTERBUS local bus interface for the Inlin..

ILC 200 UNI-PAC

2862291

PHOENIX_CONTACT

Available

Ship on today

Inline controller with an INTERBUS local bus interface for the Inline installation system, with programming facility in acc. with IEC 61131-3, complete with accessories (connector and labeling field)

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$724.48
2+$723.17
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

Inline controller

ILC 200 UNI transforms every Inline station into a distributed functional unit. ILC 200 UNI is installed below an Inline bus coupler (INTERBUS, PROFIBUS, DeviceNet™, Ethernet...). It then controls all the signals of the Inline station in every fieldbus system. This ensures maximum independence from the higher-level fieldbus system.

The functions which can be executed on ILC 200 UNI range from emergency operation functions in the event of a failure of the higher-level fieldbus, to redundancy functions and process data preprocessing, through to the distributed functional unit.

Plant engineering with its constantly changing customer requirements regarding both the fieldbus system and centralized control systems is the main field of application. ILC 200 UNI makes it possible to use identical functional units even when the higher-level fieldbus changes. This saves costs during plant engineering and at startup.

Direct fast inputs and outputs which can be used flexibly in different operating modes such as interrupt input, event counting and pulse generation ensure short response times on site.

All programming of the Inline controller is carried out with PC WORX, the automation software according to IEC 61131.

Dimensions

Width73 mm
Height140.5 mm
Depth71.5 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)0 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 75 °C
Permissible humidity (operation)5 % ... 85 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 85 % (non-condensing)
Air pressure (operation)70 kPa ... 108 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)66 kPa ... 108 kPa (up to 3500 m above mean sea level)
Shock25g, Criterion 1, according to IEC 60068-2-27
Vibration (operation)2g, criterion 1 according to IEC 60068-2-6

Control system

Programming toolPC WORX
Diagnostics toolDIAG+ from version 1.14

Mechanical design

Weight260 g
Diagnostics displayNo
Controller redundancyNo

Data interfaces

InterfaceINTERBUS local bus (master)
Connection methodInline data jumper
Transmission speed500 kBaud / 2 MBaud (can be switched)
InterfaceHigher-level INTERBUS local bus (slave)
Connection methodInline data jumper
InterfaceParameterization/operation/diagnostics
Connection methodRS-232-C, 6-pos. MINI-DIN socket (PS/2)
Transmission speed19200 Baud

Power supply

Typical current consumption250 mA (no local bus device connected during idling, bus inactive)
Supply voltage7.5 V DC (the power supply comes from the upstream bus coupler)
Supply voltage range19.2 V DC ... 30 V DC
Residual ripple±5 %
Power dissipationmax. 1.875 W
Max. total permissible current consumption of all I/O terminal blocksCommunications power (7,5 V DC) the power supply comes from the upstream bus coupler
Analog supply (24 V DC) = 0.5 A

Fieldbus function

Amount of process datamax. 4096 Bit (INTERBUS-Master)
192 Bit (INTERBUS-Slave)
Number of parameter datamax. 8 Byte (configurable)
Number of supported devicesmax. 512
Number of local bus devices that can be connectedmax. 63 (observe current consumption)
Number of devices with parameter channelmax. 62
Number of supported branch terminals with remote bus branchmax. 15

Direct I/Os

Input nameDigital inputs
Number of inputs4
Connection methodInline potential distributor
Description of the inputInterrupt input, fast counter, pulse generator
Output nameDigital outputs
Number of outputs2
Connection method2, 3, 4-wire
Maximum output current per channel500 mA
Without analog inputyes
Without analog outputyes
Without pulse direction outputNo
Number of pulse direction outputs2
Limit frequency20 kHz
Without counter inputNo
Number of inputs4
Input frequency40 kHz

IEC 61131 runtime system

Programming toolPC WORX
Program memorytyp. 384 kByte (32 K instructions (IL))
Mass storage330 kByte
Retentive mass storage8 kByte (NVRAM)
Number of control tasks8
Realtime clockIntegrated (battery backup)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2862291-ILC 200 UNI-PACEnglish127 KbytesPHOENIX CONTACT-2862291-ILC 200 UNI-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or