IB IL SGI 2/F-2MBD-PAC 2878735 PHOENIX CONTACT Inline analog strain gauge input terminal, complete with acce.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL SGI 2/F-2MBD-PAC 2878735 PHOENIX CONTACT Inline analog strain gauge input terminal, complete with acce..

IB IL SGI 2/F-2MBD-PAC

2878735

PHOENIX_CONTACT

Available

Ship on today

Inline analog strain gauge input terminal, complete with accessories (connector and labeling field), transmission speed 2 Mbaud, 2 quick inputs, 4, 6-conductor connection method

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$323.12
2+$316.06
3+$314.08
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width48.8 mm
Height136 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Net weight190 g
Mounting typeDIN rail
Operating modeProcess data operation with 3 words, PCP with 1 word
Diagnostics messagesFailure of the power supply at UANA Error message in the process data
Failure of or insufficient communications power UL I/O error message sent to the bus coupler
Peripheral fault Error message in the process data

Interfaces

DesignationInline local bus
Connection methodInline data jumper
Transmission speed2 MBit/s
Transmission physicsCopper

Inline potentials

Communications power UL7.5 V DC
Current consumption from ULtyp. 100 mA
max. 110 mA
I/O supply voltage UANA24 V DC
Current consumption from UANAtyp. 32 mA (with maximum load of 58.3 Ω when UV = 5 V)
typ. 8 mA (Without strain gauge)
Power consumptiontyp. 0.94 W

Analog inputs

Description of the inputInput channels for strain gauge
Number of inputs2
Connection method6 or 4-wire, twisted pair shielded cable
Bridge difference UdMeasuring range specified by selecting the characteristic and the bridge voltage
Bridge voltage U03.3 V
Characteristics+1 mV/V, +2 mV/V, +3 mV/V, +4 mV/V
±1 mV/V, ±2 mV/V, ±3 mV/V, ±4 mV/V
Measured value representation15 bit + sign bit

Analog outputs

Output descriptionVoltage output
Number of outputs2
Impedance> 58.3 Ω (typical; permissible total resistance of the strain gauge)
Output voltage5 V ±0,5 V
3.3 V ±0,5 V
Output currenttyp. 55 mA (With UV = 3.3 V)
typ. 85 mA (With UV = 5 V)

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2878735-IB IL SGI 2/F-2MBD-PACEnglish129 KbytesPHOENIX CONTACT-2878735-IB IL SGI 2/F-2MBD-PAC