IB IL TEMP 2 RTD-XC-PAC 2701217 PHOENIX CONTACT Inline function terminal View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL TEMP 2 RTD-XC-PAC 2701217 PHOENIX CONTACT Inline function terminal

IB IL TEMP 2 RTD-XC-PAC

2701217

PHOENIX_CONTACT

Inline function terminal

More details


I/O

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $414.50
Unit price: $414.50

Quantity Price
1+$414.50
2+$392.76
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2701217
Packing unit1 pc
Catalog pagePage 165 (C-6-2017)
GTIN4046356728829
Weight per Piece (excluding packing)67.000 g
Custom tariff number85389091
Country of originDE (Germany)

Note

Utilization restriction1

Dimensions

Dimensional drawing
Width12.2 mm
Height136.8 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C (Standard)
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight67 g
Note on weight specificationswith connector
Operating modeProcess data operation with 2 words

Interfaces

DesignationInline local bus
No. of channels2
Connection methodInline data jumper
Transmission speed500 kbps

Inline potentials

DesignationCommunications power (UL)
Supply voltage7.5 V DC (via voltage jumper)
Current consumptiontyp. 43 mA
max. 60 mA
DesignationSupply of analog modules (UANA)
Supply voltage24 V DC (via voltage jumper)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 11 mA
max. 18 mA
Power consumptiontyp. 587 mW

Analog inputs

Number of inputs2
Input nameAnalog RTD inputs
Description of the inputInput for resistive temperature sensors
Connection methodSpring-cage connection
Connection technology2, 3, 4-wire
Note regarding the connection technologyshielded
Sensor types (RTD) that can be usedPt, Ni, KTY, Cu sensors, linear resistors
Linear resistance measuring range0 Ω ... 400 Ω
0 Ω ... 4 kΩ
Measuring principleSuccessive approximation
Measured value representation16 bits two's complement and other
A/D conversion timetyp. 120 µs (per channel)
Resolution A/D16 bit (15 bit + sign bit)
Process data update32 ms (both channels with 3-wire technology)

Electrical isolation

Test section7.5 V supply (bus logics)/24 V analog supply (analog I/O) 500 V AC 50 Hz 1 min.
7.5 V supply (bus logics) / functional earth ground 500 V AC 50 Hz 1 min.
24 V analog supply (analog I/O) / functional earth ground 500 V AC 50 Hz 1 min.

Standards and Regulations

Connection in acc. with standardCUL
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.