IB IL TEMP 2 RTD-PAC 2861328 PHOENIX CONTACT Inline analog input terminal, complete with accessories (connec.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL TEMP 2 RTD-PAC 2861328 PHOENIX CONTACT Inline analog input terminal, complete with accessories (connec..

IB IL TEMP 2 RTD-PAC

2861328

PHOENIX_CONTACT

Available

Ship on today

Inline analog input terminal, complete with accessories (connector plug and labeling field), 2 inputs, RTD (resistance temperature detector), 2-, 3-, 4-wire connection technology

More details


Programmable Logic Controllers Plcs

AUTOMATION Industrial Automation - PHOENIX CONTACT

Control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

Using these analog input terminals, it is possible to measure signals from conventional thermocouples and resistance thermometers.

The terminals are configured for connection to various types of sensors. The user can configure the different sensor characteristic curves himself via process data. It is thus possible to attain the best possible adaptations in very different applications.

The Inline terminals can be labeled using hinged labeling fields. The fields have insert cards that can be labeled individually to suit the application. Additionally, there is the proven ZBFM-6... Zack strip for labeling the terminal points.

Dimensions

Width12.2 mm
Height136.8 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Net weight67 g
Note on weight specificationswith connector
Mounting typeDIN rail

Interfaces

DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s
Transmission physicsCopper

Inline potentials

Communications power UL7.5 V DC (via voltage jumper)
Current consumption from ULmax. 60 mA
typ. 43 mA
I/O supply voltage UANA24 V DC
Current consumption from UANAmax. 18 mA
typ. 11 mA
Power consumptiontyp. 587 mW
max. 882 mW

Analog inputs

Number of inputs2
Input nameAnalog RTD inputs
Description of the inputInput for resistive temperature sensors
Connection methodSpring-cage connection
2, 3-conductor
Sensor types (RTD) that can be usedPt, Ni, KTY, Cu sensors, linear resistors
Linear resistance measuring range0 Ω ... 400 Ω
0 Ω ... 4 kΩ
Measuring principleSuccessive approximation
Measured value representation16 bits two's complement and other
A/D conversion timetyp. 120 µs (per channel)
Resolution A/D16 bit (15 bit + sign bit)
Process data update30 ms

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2861328-IB IL TEMP 2 RTD-PACEnglish125 KbytesPHOENIX CONTACT-2861328-IB IL TEMP 2 RTD-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or