PSI-MODEM-SHDSL/SERIAL 2313669 PHOENIX CONTACT Industrial SHDSL SERIAL permanent line modem for V.24 (RS-232.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PSI-MODEM-SHDSL/SERIAL 2313669 PHOENIX CONTACT Industrial SHDSL SERIAL permanent line modem for V.24 (RS-232..

PSI-MODEM-SHDSL/SERIAL

2313669

PHOENIX_CONTACT

Available

Ship on today

Industrial SHDSL SERIAL permanent line modem for V.24 (RS-232)/RS-422/RS-485 point-to-point and linear structures. Serial data transmission of up to 2000 kbps on the plant's own cables, integrated diagnostic function, two configurable alarm outputs.

More details


Converters

INTERFACE Signal converters, switching devices, and power supply units - PHOENIX CONTACT

Interface converter, separators and modems. Serial - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width35 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (for derating, see technical documentation)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Altitude5000 m (For restrictions see manufacturer's declaration)
Degree of protectionIP20
Noise immunityEN 61000-6-2

General

Electrical isolationDIN EN 50178 (VCC, RS-232 // RS-422, RS-485 // DSL (A) // DSL (B) // FE)
Test voltage data interface/power supply1.5 kVrms (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016)
Noise emissionEN 55011
Net weight339.4 g
Housing materialPA 6.6-FR
Colorgreen
MTBF1004 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
199 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
MTTF693 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day))
301 Years (SN 29500 standard, temperature 40 °C, operating cycle 34.25 % (5 days a week, 12 hours a day))
121 Years (SN 29500 standard, temperature 40°C, operating cycle 100 % (7 days a week, 24 hours a day))
ConformanceCE-compliant
ATEXEx II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
UL, USA / CanadacULus listed UL 508

Power supply

Nominal supply voltage24 V DC ±5 % (as an alternative or redundant, via backplane bus contact and system current supply)
5 V DC (configuration only, via mini-USB type B)
Supply voltage range18 V DC ... 30 V DC
Typical current consumption< 180 mA (24 V DC)
Connection methodCOMBICON plug-in screw terminal block

Serial interface

Interface 1V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
InterfaceRS-232
Connection methodD-SUB-9 plug
Transmission lengthmax. 15 m
Termination resistor390 Ω - 180 Ω - 390 Ω (can be connected)
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.13
Data flow control/protocolsSoftware handshake, Xon/Xoff, hardware handshake (RTS/CTS), 3964R-compatible, Modbus (RTU/ASCII), transparent protocol - additional protocols supported
Serial transmission speed0.11/0.3/1.2/2.4/4.8/9.6/19.2/38.4/57.6/115.2/230.4 kbps, NRZ
Interface 2SHDSL interface according to ITU-T G.991.2.bis
Connection method2 x 2-pos. COMBICON plug-in screw terminal blocks
Transmission lengthup to 20 km (Depending on data rate and cable cross section)
Serial transmission speed4-wire operation: 64 kbps ... 30 Mbps
2-wire operation: 32 kbps ... 15.3 Mbps
Interface 3USB 2.0
Connection methodMini-USB type B, 5-pos.
Transmission length< 5 m (only for configuration and diagnostics)
Interface 4RS-422 interface in acc. with ITU-T V.11, EIA/TIA-422, DIN 66348-1
InterfaceRS-422
Connection methodPlug-in/screw connection via COMBICON
File format/codingSerial asynchronous UART/NRZ, 7/8 data bits, 1/2 stop bits, 1 parity bit (even, odd, mark, space, none), 9/10/11-bit character length
Transmission length≤ 1200 m
Termination resistor390 Ω - 180 Ω - 390 Ω (can be connected)
Data flow control/protocolsAutomatic control // Modbus RTU/ASCII
Serial transmission speed1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000 kbps, NRZ
Interface 5RS-485 interface, in acc. with EIA/TIA-485, DIN 66259-4/RS-485 2-wire
InterfaceRS-485
Connection methodPlug-in/screw connection via COMBICON
File format/codingSerial asynchronous UART/NRZ, 7/8 data, 1/2 stop, 1 parity, 10/11-bit character length
Transmission lengthup to 1200 m
Termination resistor390 Ω - 180 Ω - 390 Ω (can be connected)
Protocols supportedTransparent, including 3964R protocol
Data flow control/protocolsAutomatic control // Modbus RTU/ASCII
Serial transmission speed1.2/2.4/4.8/7.0/9.6/19.2/38.4/57.6/75/93.75/115.2/136/187.5/375/500/1500/2000 kbps, NRZ

Function

ManagementUser-friendly software: Guided configuration, plausibility checks, diagnostic functions, log book
Status and diagnostic indicatorsLEDs: VCC (supply voltage), RD/TD (serial data traffic), ERR (errors), TERM (termination resistor active), RS-232 (RS-232 active)2 x LINK / 2 x STAT (DSL data traffic port A and port B), DIAG (diagnostic messages)

Digital outputs

Output nameDigital output
Number of outputs2
Voltage output signaldepending on the operating voltage
Current output signal≤ 150 mA (Short-circuit-proof)
Behavior of the outputsDeactivated for device supply via T-BUS

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2313669-PSI-MODEM-SHDSL/SERIALEnglish231 KbytesPHOENIX CONTACT-2313669-PSI-MODEM-SHDSL/SERIAL

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or