HC-B 6-I-CT-M 1648157 PHOENIX CONTACT HEAVYCON male insert, B6 series, 6-pos., for crimp contacts View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HC-B 6-I-CT-M 1648157 PHOENIX CONTACT HEAVYCON male insert, B6 series, 6-pos., for crimp contacts

HC-B 6-I-CT-M

1648157

PHOENIX_CONTACT

10

Available

Ship on today

HEAVYCON male insert, B6 series, 6-pos., for crimp contacts

More details


Core End Sleeves Cable Crimp

PLUSCON Field cabling - PHOENIX CONTACT

Heavy industrial connectors - PLUSCON heavy - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+$6.25
40+$5.88
70+$5.77
100+$5.71
130+$5.67
*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



General

NoteFor HEAVYCON ADVANCE and HEAVYCON housing of B6 type, crimp contacts CK 2,5-ED (crimp contacts not included in the scope of supply).
Connection methodCrimp connection
Pollution degree3
Overvoltage categoryIII
Constructional and testing regulationsDIN EN 61984
DIN EN 60664
IEC 60352
Number of positions6+PE
Insertion/withdrawal cycles≥ 500
TypeB6
Connection in acc. with standardIEC / EN
Conductor cross section0.5 mm² ... 4 mm²
Connection cross section AWG20 ... 12
Stripping length of the individual wire7.5 mm
Assembly instructionsCoding also using the CP-HC (1686478) coding profiles. HC-B6../ HC-B10..for two coding profiles. HC-B16../ HC-B24..for four coding profiles.
ConnectionFor housing type B6. Connectors may only be inserted when there is no load/the power is switched off. Use a screwdriver to remove the crimp contacts. The opening for the screwdriver is next to the opening where the conductor is inserted.

Ambient conditions

Ambient temperature (operation)-40 °C ... 125 °C (including heating up of contacts)
Degree of protectionIP20

Material data

Flammability rating according to UL 94V0
Contact materialCopper alloy
Contact surface materialAg (alternatively Au)
Contact carrier materialPA
Standards/regulationsPA: Fire protection in rail vehicles - requirement sets R22 and R23 acc. to DIN EN 45545-2 (Risk level HL1 - HL2)
PA: Fire protection in rail vehicles - requirement set R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)

Electrical characteristics

Rated voltage (III/3)500 V
Rated surge voltage6 kV
Rated current16 A

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-1648157-HC-B 6-I-CT-MEnglish140 KbytesPHOENIX CONTACT-1648157-HC-B 6-I-CT-M

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review