ST 10-PE 3036136 PHOENIX CONTACT Ground modular terminal block View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ST 10-PE 3036136 PHOENIX CONTACT Ground modular terminal block

ST 10-PE

3036136

PHOENIX_CONTACT

50

Ground modular terminal block

More details


Modular TBs

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Quantity Price
50+$5.12
100+$4.86
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Key Commercial Data

Orderkey3036136
Packing unit50 pc
Catalog pagePage 189 (C-1-2017)
GTIN4017918819095
Weight per Piece (excluding packing)33.870 g
Custom tariff number85369010
Country of originPL (Poland)

General

Number of positions1
Number of levels1
Number of connections2
Nominal cross section10 mm²
Colorgreen-yellow
Insulating materialPA
Flammability rating according to UL 94V0
Area of applicationRailway industry
Machine building
Plant engineering
Process industry
Rated surge voltage8 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
Open side panelYes
Shock protection test specificationDIN EN 50274 (VDE 0660-514):2002-11
Back of the hand protectionguaranteed
Finger protectionguaranteed
Oscillation, broadband noise test resultTest passed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):2018-05
Test spectrumService life test category 2, bogie-mounted
Test frequencyf1= 5 Hz to f2= 250 Hz
ASD level6.12 (m/s2)2/Hz
Acceleration3.12 g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
Shock test resultTest passed
Test specification, shock testDIN EN 50155 (VDE 0115-200):2018-05
Shock formHalf-sine
Acceleration30g
Shock duration18 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))125 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)27,5 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width10.2 mm
End cover width2.2 mm
Length71.5 mm
Height NS 35/7,550.3 mm
Height NS 35/1557.8 mm

Connection data

NotePlease observe the current carrying capacity of the DIN rails.
Connection methodSpring-cage connection
Stripping length18 mm
Connection in acc. with standardIEC 60947-7-2
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.16 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.6
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.10 mm²
Min. AWG conductor cross section, flexible24
Max. AWG conductor cross section, flexible8
Conductor cross section flexible, with ferrule without plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.10 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.25 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.10 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.1.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.2.5 mm²
Connection in acc. with standardIEC/EN 60079-7
Conductor cross section solid min.1.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section AWG min.16
Conductor cross section AWG max.6
Conductor cross section flexible min.1.5 mm²
Conductor cross section flexible max.10 mm²
Internal cylindrical gageA6

Standards and Regulations

Connection in acc. with standardCSA
IEC 60947-7-2
Flammability rating according to UL 94V0
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.