Key Commercial Data

Orderkey3005112
Packing unit50 pc
NoteMade to Order (non-returnable)
Catalog pagePage 458 (C-1-2017)
GTIN4017918091057
Weight per Piece (excluding packing)33.770 g
Custom tariff number85369095
Country of originPL (Poland)

General

Number of levels1
Number of connections2
Nominal cross section16 mm²
Colorblack
Insulating materialPA
Flammability rating according to UL 94V2
Maximum power dissipation for nominal condition2.43 W
FuseG / 5 x 20
Fuse typeGlass / ceramics / ...
Rated surge voltage4 kV
Degree of pollution3
Overvoltage categoryIII
Insulating material groupI
LED voltage range5 V AC/DC ... 15 V AC/DC
LED current range0.5 mA ... 2.5 mA
Connection in acc. with standardIEC 60947-7-3
Maximum load current10 A
Nominal current IN10 A
Nominal voltage UN500 V
800 V (As a disconnect terminal block)
Open side panelNo
Oscillation, broadband noise test resultTest passed
Test specification, oscillation, broadband noiseDIN EN 50155 (VDE 0115-200):2008-03
Test spectrumService life test category 1, class B, body mounted
Test frequencyf1= 5 Hz to f2= 150 Hz
ASD level1.857 (m/s2)2/Hz
Acceleration0,8 g
Test duration per axis5 h
Test directionsX-, Y- and Z-axis
Shock test resultTest passed
Test specification, shock testDIN EN 50155 (VDE 0115-200):2008-03
Shock formHalf-sine
Acceleration5 g
Shock duration30 ms
Number of shocks per direction3
Test directionsX-, Y- and Z-axis (pos. and neg.)
Relative insulation material temperature index (Elec., UL 746 B)130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21))130 °C
Static insulating material application in cold-60 °C
Behavior in fire for rail vehicles (DIN 5510-2)Test passed
Flame test method (DIN EN 60695-11-10)V0
Oxygen index (DIN EN ISO 4589-2)>32 %
NF F16-101, NF F10-102 Class I2
NF F16-101, NF F10-102 Class F2
Surface flammability NFPA 130 (ASTM E 162)passed
Specific optical density of smoke NFPA 130 (ASTM E 662)passed
Smoke gas toxicity NFPA 130 (SMP 800C)passed
Calorimetric heat release NFPA 130 (ASTM E 1354)28 MJ/kg
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Dimensions

Width12 mm
Length62 mm
Height NS 35/7,557.2 mm
Height NS 35/1564.7 mm
Height NS 3262.2 mm

Connection data

Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.16 mm²
Conductor cross section flexible min.0.5 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.6
Conductor cross section flexible, with ferrule without plastic sleeve min.0.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max.10 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.0.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve max.10 mm²
Cross section with insertion bridge, solid max.10 mm²
Cross section with insertion bridge, stranded max.10 mm²
2 conductors with same cross section, solid min.0.5 mm²
2 conductors with same cross section, solid max.4 mm²
2 conductors with same cross section, stranded min.0.5 mm²
2 conductors with same cross section, stranded max.4 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, min.0.5 mm²
2 conductors with same cross section, stranded, ferrules without plastic sleeve, max.4 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, min.0.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic sleeve, max.10 mm²
Cross section with insertion bridge, solid max.10 mm²
Cross section with insertion bridge, stranded max.10 mm²
Connection methodScrew connection
Stripping length11 mm
Internal cylindrical gageB6
Screw threadM4
Tightening torque, min1.5 Nm
Tightening torque max1.8 Nm

Standards and Regulations

Connection in acc. with standardUL
IEC 60947-7-3
Flammability rating according to UL 94V2
Fire protection for rail vehicles (DIN EN 45545-2) R22HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26HL 1 - HL 3

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.